MEX-XB100BT
Pin No.
Pin Name
57
MEC_LIMIT
58
Vcc
59
KEY_ACK0
60
MEC_LOAD
61
Vss
62
PVcc
63
XM_RX
64
DEBUG_RX
65
BT_RX
66
MD_CLKS
67
RTC_X1
68
RTC_X2
69
PLLVcc
70
EXTAL
71
XTAL
72, 73
Vss
74
NMI
75
Vss
76
RES
77
PVcc
78
FAULT
79
ILL_IN
80
CLIP_DET
81
RC_IN0
82, 83
KEY_IN0, KEY_IN1
84
RC_IN1
85
FET_THM
86
AVcc
87
Vss
88
Avref
89
BSCANP
90
PVcc
91
Paradisso_BCK
92
NC
93
Vss
94
SYNC_ON
95
Vcc
96
XM_PWR
97
TRST
98
TDO
99
TDI
100
TMS
101
TCK
102
Vss
103
DCDC_EN
104
EN_SYS
105
Vcc
106
PWR_ECO
107
Vss
108
USB_OVR
109
PVcc
110, 111
NC
112
BT_PWR
113
NC
114
BT_RST
115
REMOTE1K
50
I/O
I
Limit in detection switch input terminal
-
Power supply terminal (+1.18V) (for internal)
I
Key acknowledge signal (wake up signal) input terminal
O
Loading motor drive signal (loading direction) output terminal
-
Ground terminal
-
Power supply terminal (+3.3V) (for I/O)
I
Serial data input from the SIRIUSXM in connector (US and Canadian models only)
I
Receive data input terminal for the debug
I
Serial data input from the BT module
I
Fixed at "L" in this unit
I
System clock input terminal (32.768 kHz)
O
System clock output terminal (32.768 kHz)
-
Power supply terminal (+1.18V) (for PLL)
I
System clock input terminal (13.333 MHz)
O
System clock output terminal (13.333 MHz)
-
Ground terminal
I
Fixed at "H" in this unit
-
Ground terminal
System reset signal input from the reset signal generator and RESET switch
I
For several hundreds msec. after the power supply rises, "L" is input, then it change to "H"
-
Power supply terminal (+3.3V) (for I/O)
I
Fault signal input from the power amplifi er
I
Illuminate line detection signal input terminal
Clip detection or over temperature warning signal input from the power amplifi er
I
"L": clip or over temperature
I
Rotary commander key input terminal
I
Front panel key input terminal
I
Rotary commander shift key input terminal
I
Thermal detection signal input terminal
-
Power supply terminal (+3.3V) (analog system)
-
Ground terminal
-
Reference power supply (+3.3V) input terminal (analog system)
I
Fixed at "L" in this unit
-
Power supply terminal (+3.3V) (for I/O)
I
Audio clock signal input terminal
-
Not used
-
Ground terminal
O
Not used
-
Power supply terminal (+1.18V) (for internal)
Power supply on/off control signal output to the SIRIUSXM in connector
O
(US and Canadian models only)
I
Reset signal input terminal for the JTAG
O
Data output terminal for the JTAG
I
Data input terminal for the JTAG
I
Mode selection signal input terminal for the JTAG
I
Clock signal input terminal for the JTAG
-
Ground terminal
O
Power supply on/off control signal output terminal for the DC/DC converter
O
Power on/off control signal output to the regulator
-
Power supply terminal (+1.18V) (for internal)
Low power mode selection signal output to the regulator and VBUS switch
O
"L": low power mode
-
Ground terminal
I
USB over current detection signal input from the regulator
-
Power supply terminal (+3.3V) (for I/O)
-
Not used
O
Power on/off control signal output terminal for the Bluetooth section
-
Not used
O
Reset signal output to the BT module
O
Rotary commander key control signal output terminal
Description
Not used
"H": motor on
Not used
"L": fault
Not used
Not used
Not used
Not used
Not used
Not used
"H": power on
"L": over current
"L": reset
"L": reset
"H": power on
"H": power on
"H": power on

Advertisement