10

FLOW DIAGRAMS

10.1

Refrigerator Not Operating

Refer to Section
6.2.1
Repair or replace
faulty components
With FC door
closed and PC
door open, press
Mode button
Is there 12V
DC between the
power/control module
and the display
module?
No
Replace
power/control
module
Is there
power to the
refrigerator?
Yes
Does the
display
module
Yes
indicate a
fault code?
Has product
been
No
initialised?
Yes
Is there 12V
DC at the
No
display
module?
Yes
Replace display
module
Check house
No
outlet socket
Is there
power to the
No
power/control
module?
Yes
Are any
L.E.D.s on at
No
the display
module?
Yes
Is the
compressor
warm?
Yes
Refer to Section
10.12
48
No
Repair or replace
faulty components
Refer to Section
10.13