Fisher & Paykel 790 Active Smart Service Manual page 44

Hide thumbs Also See for 790 Active Smart:
Table of Contents

Advertisement

FC TOO WARM
Total Compartment Warm
TOTAL CABINET TOO WARM
FC COOLING - PC WARMING
ALARM ON
FAULT DISPLAYED, NO ALARM
LIGHT NOT FUNCTIONING
CONSOLE NO L.E.D. LIGHTS
* Iced up evaporator
* No refrigeration
* No refrigeration
* Iced up evaporator
* Iced up return duct
* Defrost heater
* Sensors (alarm will sound
and fault code will be
displayed)
* Door switch fault
* Display flashing fault code,
but no alarm sounding
* Blown bulb
* Cabinet type
* Poor connection
* Power/control module no
power
* Power/control module not
initialized
-
Check defrost element is working (alarm will sound and
fault code will be displayed if faulty), replace if faulty.
-
Check doors are sealing or have they been left open,
adjust and advise customer.
-
FC fan jammed, clear restriction, replace fan if necessary.
-
Check defrost sensor position, reposition onto chassis if
not already there.
-
Does cabinet run? If no check power supplies. If yes
check refrigeration system.
/ fully flooded evaporator, if not check for leak.
-
Does cabinet run? If no check power supplies. If yes
check refrigeration system. If running, check for live
frost/fully flooded evaporator. If not, check for leak.
-
Compressor is not running, check power/control module
voltage outputs. Check compressor and ancillaries.
-
Check reed switches are working OK by entering the
Input/Output mode (refer to Section 6.2.4) and placing a
magnet over the reed switch
-
Check defrost circuit continuity
-
Doors sealing, adjust
-
PC fan is running, if not refer PC too warm
-
De-ice duct area
-
Check PC duct insulation for good seal in return duct
-
Check doors are sealing
-
Check display for any fault code
-
Check defrost element continuity
-
Put cabinet into manual defrost, wait for defrost relay to
"click" on (2 ½ minutes after pressing buttons)
-
If no "click", check power/control module
-
If "click" heard, check the defrost heater 110v output at the
power/control module
-
Check console for fault codes 0-5
-
Sensors above or below limit, refer thermistor service
table in service manual
-
Check that no fault code is shown on the display
-
Check that PC/FC doors activate reed switches
-
Check also reed switches with magnet
-
Check wiring harness to power/control module
-
Alarm has been switched off by user
-
Piezo alarm faulty, replace power/control module
-
Check power supply to socket 7Volts, if nil check plug at
display module
-
Check continuity of bulb, if nil replace
-
Power / console module not initialised, close FC door and
press compartment select button
-
Spread halogen bulb legs
-
Check lamp holder, replace where possible
-
Check connector on display module
-
Check harness and plugs on 5 way display module
harness at both ends
-
Initiate cabinet
-
Initialize power/control module, close FC door and push
any button on display module
-
If raspberry noise still made, check door switches
44
If running check for live frost