Item
Cooling capacity
Power source
Power consumption
Power factor
Running current
Starting current
Operating noise
(SPL)
Refrigerant
Refrigerant control
Interconnection
pipe
Condensate drain pipe diameter
INDOOR UNIT Model
Appearance colour
Dimensions
Net weight
Heat exchanger type
Indoor fan type
Air volume
Fan motor output
Air filter
OUTDOOR UNIT Model
Appearance colour
Dimensions
Net weight
Heat exchanger type
Outdoor fan type
Air flow volume
Fan motor output
Compressor
Protective device
Specifications are subject to change without notice
1. SPECIFICATIONS
Model
kW
Phase
V
Hz
kW
%
A
A
dB(A)
Indoor Unit (High, Med, Low)
dB(A)
Outdoor Unit
Name of Refrigerant
kg
Charge Volume
g/m
Add. Volume (20-30m)
mm
Larger side size
Coupler style
Smaller side size
mm
Coupler style
m
Standard length
Maximum actual pipe length
m
(of one way)
Maximum height difference
If Indoor Unit higher
m
m
If Outdoor Unit higher
mm
Height
mm
mm
Width
mm
Depth
kg
m
W
mm
Height
Width
mm
mm
Depth
kg
m
W
Model
kW
Output
RAV-264C-PE
7.1
1
220-240
50
COOLING
3.1
90
15.0
80
45/41/37
53
R407C
1.9
35
Capillary tube
¿15.9
Flare
¿9.5
Flare
7.5
30
15
30
¿20 (OD)
RAV-264C-PE
Silky
Mist
188
1,230
640
28
Finned tube
Multi-blade fan
1,200
3
/h
34
Washable
RAV-264A-PE
Bronze white (Munsell 6Y7.5/1)
790
880
310
64
Finned tube
Propeller fan
/h
3
3,000
63
PG460X3F-4MS
2.2
fuse, crankcase heater,
inner overload relay
7
RAV-264C-PE
7.1
3
380-415
50
COOLING
2.9
85
4.9
25
45/41/37
53
R407C
1.9
35
Capillary tube
¿15.9
Flare
¿9.5
Flare
7.5
30
15
30
¿20 (OD)
RAV-264C-PE
Silky
Mist
188
1,230
640
28
Finned tube
Multi-blade fan
1,200
34
Washable
RAV-264A8-PE
Bronze white (Munsell 6Y7.5/1)
790
880
310
64
Finned tube
Propeller fan
3,000
63
YG460X3F-MS
2.2
fuse, crankcase heater, overcurrent
relay, reverse phase protector,
bi-metal thermostat