A-3
Welder Enclosure - The complete welder is rubber
mounted on a rugged steel "C" channel base.
The output terminals are placed at the side of the
machines so that they are protected by the door. The
output terminals are labeled (+) and (-).
Cranking System - A 12 volt electric starter is stan-
dard.
Air Cleaner - Heavy duty two stage dry type.
Muffler - A muffler and stainless steel exhaust outlet
elbow are standard.
Fuel / Hour / LED gauge - A meter to record hours of
operation, show fuel status, battery charging fault LED
and engine fault LED.
Engine Protection - The system shuts the engine
down in the event of sudden low oil pressure or high
coolant temperature. A warning light on the control
panel will indicate such a fault. To reset the engine for
restarting, turn the ignition switch off then on. Refer to
Troubleshooting section for all warning light fault
codes.
Battery Charging Light - A warning indicator light for
Low/No battery charge. The light is off when the sys-
tems are functioning properly. The light will come on if
there is a Low/No battery condition but the machine
will continue to run.
NOTE: The light will come on when the Run/Stop
switch is in the "ON" position. It will come on during
cranking and stay on until the engine starts. After,
starting the engine the light will go off unless a
Low/No battery condition exists.
Oil Drain Valve - A ball valve, hose and clamp are
standard.
Remote Control - The Remote / Local Switch and
Receptacle are standard.
INSTALLATION

PRE-OPERATION INSTALLATION

Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer's
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
------------------------------------------------------------------------
------------------------------------------------------------------------
------------------------------------------------------------------------
See additional warning information at the
front of this operator's manual.
-----------------------------------------------------------

ExHAUST SPARK ARRESTER

Some federal, state or local laws may require that
engines be equipped with exhaust spark arresters
when they are operated in certain locations where
unarrested sparks may present a fire hazard. The
standard muffler included with this welder does not
qualify as a spark arrester. When required by local
regulations, a suitable spark arrester must be installed
and properly maintained.
Use of an incorrect arrester may lead to engine damage
or performance loss. Contact the engine manufacturer
for specific recommendations.
------------------------------------------------------------------------
LOCATION / VENTILATION
Always operate the welder with the doors closed.
Leaving the doors open changes the designed air flow
and may cause overheating.
The welder should be located to provide an unrestrict-
ed flow of clean, cool air. Also, locate the welder so
that engine exhaust fumes are properly vented to an
outside area.
®
SAE-300
HE
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
ENGINE ExHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.
MOVING PARTS can injure.
• Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.