Page 1
Operator’s Manual ® SAE-400 DC ARC WELDING POWER SOURCE For use with machines having Code Numbers: 11808 Need Help? Call 1.888.935.3877 Register your machine: to talk to a Service Representative www.lincolnelectric.com/register Authorized Service and Distributor Locator: Hours of Operation: www.lincolnelectric.com/locator 8:00 AM to 6:00 PM (ET) Mon.
Page 2
THANK YOU FOR SELECTING A QUALITY PRODUCT BY KEEP YOUR HEAD OUT OF THE FUMES. LINCOLN ELEC TRIC. DON’T get too close to the arc. Use corrective lenses if necessary to stay a reasonable distance away from the arc. READ and obey the Material Safety PLEASE EXAMINE CARTON AND EQUIPMENT FOR Data Sheet (MSDS) and the warning DAMAGE IMMEDIATELY...
Page 3
American Welding Society, P.O. Box 351040, Miami, Florida 33135 or ELECTRIC AND CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” MAGNETIC FIELDS MAY booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199. BE DANGEROUS BE SURE THAT ALL INSTALLATION, OPERATION, 2.a.
Page 4
SAFETY ELECTRIC SHOCK ARC RAYS CAN BURN. CAN KILL. 3.a. The electrode and work (or ground) circuits are 4.a. Use a shield with the proper filter and cover plates to protect your electrically “hot” when the welder is on. Do not eyes from sparks and the rays of the arc when welding or touch these “hot”...
Page 5
SAFETY WELDING AND CUTTING CYLINDER MAY EXPLODE IF SPARKS CAN CAUSE DAMAGED. FIRE OR EXPLOSION. 7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used 6.a. Remove fire hazards from the welding area. If and properly operating regulators designed for this is not possible, cover them to prevent the the gas and pressure used.
The welder should be located to provide an unrestricted ------------------------------------------------------------------------ flow of clean, cool air to the cooling air inlets and to avoid restricting the cooling air outlets. Also, locate the welder so that the engine exhaust fumes are properly vented to an outside area. SAE-400 ®...
5. Proper preventative maintenance of trailer. 6. Conformance with federal, state and local laws. For highway use, consult applicable federal, state and local laws regarding specific requirements for use on public highways, such as brakes, lights, fend- ers, etc. SAE-400 ®...
Be careful to charge the bat- tery with the correct polarity. Make sure that the battery Lincoln Electric selects high quality, heavy-duty indus- is level while charging. trial engines for the portable welding machines we offer.
The U.S. National Electrical Code lists a number of alternate means of grounding electrical equipment. A machine grounding stud marked with the symbol is provided on the welding generator frame foot. SAE-400 ®...
• Insulate yourself from the work and ground. for pipe thawing is not approved by the CSA, nor is • Always wear dry insulating gloves. it recommended or supported by Lincoln Electric. • Do not use AC welder if your clothing, gloves or ------------------------------------------------------------------------ work area is damp or if working on, under or inside workpiece.
RECOMMENDED APPLICATIONS OTHER FEATURES • Perkins 4-cylinder, water cooled diesel engine. WELDER Designed for long life, easy maintenance and excel- The SAE-400 provides excellent constant current DC ® lent fuel economy. welding output for stick (SMAW) welding. The field • Engine protection system shuts the engine down for installed optional CV Adapter (K385-[ ]) provides up to low engine oil pressure or high coolant temperature.
The “Job Selector” is usually set in the black range because it provides a soft “Buttering “ arc desired for most welding. Some operators prefer to set the “Job Selector” in the red range for a snappy “Digging” arc when welding vertical up or overhead. SAE-400 ®...
OPERATION AUXILIARY POWER CONTROLS RESIDUAL CURRENT DEVICE 120 VAC Receptacles The SAE-400 is configured with a Residual Current ® Device (RCD) to protect all receptacles against current One 20 amp, (each side) 120VAC (5-20R) NEMA leakage (eg. to ground) from all receptacles.
(maximum 60 seconds). Press the Glow Plug and the Start button at the same time. When the engine starts running, release both buttons. If the engine fails to start in 20 seconds, wait 30 seconds and repeat the above procedure. SAE-400 ®...
The use of an arc welder for pipe thawing is not approved by the CSA, nor is it recommended or supported by Lincoln Electric. ------------------------------------------------------------------------ SAE-400 ®...
Remove loose dirt from element with compressed air or water hose directed from inside out. Compressed Air: 100 psi maximum. The filter should never be removed while the engine is running. SAE-400 ®...
Page 20
MAINTENANCE COMMUTATOR AND BRUSH MAINTENANCE COOLING SYSTEM WARNING The SAE-400 ® is equipped with a pressure radiator. Keep the radiator cap tight to prevent loss of coolant. Uncovered rotating equipment can be dangerous. Clean and flush the cooling system periodically to pre- Use care so your hands, hair, clothing or tools do vent clogging the passage and overheating the engine.
Note: The element will only go on one way. Never use excessive force when mounting the element to ------------------------------------------------------------------------ the header. SAE-400 with integral spark arresting mufflers: ® 5. Slide the quick change ring up over the element and Service spark arrester every 250 hours.
HOW TO USE TROUBLESHOOTING GUIDE WARNING Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. SAE-400 ®...
Page 24
CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. SAE-400 ®...
Page 25
CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. SAE-400 ®...
Page 26
RCD circuit by pressing “Reset” button. CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. SAE-400 ®...
Page 29
This parts list is provided as an informative guide only. It was accurate at the time of printing. These pages are only updated on the Service Navigator DVD and in Lincoln Electricʼs official Parts Book (BK-34). When ordering parts, always refer to Lincoln Electricʼs official Parts Book (BK-34) for the latest pages.
Page 30
P-692-A.1 P-692-A.1 SAE-400 ® For Code: 11808 Do Not use this Parts List for a machine if its code number is not listed. Contact the Service Department for any code numbers not listed. Use the Illustration of Sub-Assemblies page and the table below to determine which sub assembly page and column the desired part is located on for your particular code machine.
Page 31
P-692-A.2 P-692-A.2 SAE-400 ® For Code: 11808 Do Not use this Parts List for a machine if its code number is not listed. Contact the Service Department for any code numbers not listed. Use the Illustration of Sub-Assemblies page and the table below to determine which sub assembly page and column the desired part is located on for your particular code machine.
Page 32
DESCRIPTION ...............PART NUMBER For SAE-400: CV Adapter .
Page 46
This will aid Lincoln in supplying the correct and latest board along with any necessary jumpers or adapters. The dash number brackets [ ] have purposely been left blank so as to eliminate errors, confusion and updates. 04-03-2012 SAE-400 ®...
Page 59
Brush Holder Washer Brush Holder Stud Retainer Assembly S27088-1 Lock Washer E106A-3 5/16-18 x .75 HHCS CF000040 Brush Holder Spring T8495 Brush Holder Spring Clip Lock Washer E106A-3 5/16-18 x .75 HHCS T10082-29 NSS - Not Sold Separately 04-03-2012 SAE-400 ®...
Page 60
Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice.