Refrigeration pressure data
Table 2 – Compressor data
Compressor current draw
Air-cooled
Ambient air temp.
60 F/15.6 C
Locked rotor amps
58.8
Table 3 – Gearmotor data
Gearmotor current
Locked rotor amps
Air-cooled icemaker capacity/24 hrs.
Ambient Air Temperature ˚F/˚C
60
70
F
16
21
C
50
468
417
212
189
10
450
402
60
16
204
182
432
387
70
196
176
21
80
410
369
186
175
27
387
351
90
32
176
159
Air-cooled Icemaker
Refrigeration Pressure
Discharge Pressure/Suction Pressure
Ambient air temperature ˚F/˚C
60/16
˚F/˚C
174/23
245/31
50/10
174/23
244/30
70/21
190/25
265/32
90/32
70 F/21.1 C
6.3A
6.5A
2.25A (nominal)
14A
80
90
100
27
32
38
366
317
268
lbs.
166
144
122
kg.
354
298
243
lbs.
161
135
110
kg.
342
280
217
lbs.
155
127
98
kg.
328
271
214
lbs.
149
123
97
kg.
314
262
210
lbs.
142
119
95
kg.
80/27
100/38
psi
237/37
326/38
psi
psi
347/40
80 F/26.7 C
90 F/32.2 C
6.7A
6.9A
22
100 F/37.8 C
7.1A