DATA

5
MS09NW, MS12NN, MS15NN, MS17NN

1. PERFORMANCE DATA

1) COOLING CAPACITY
Indoor air
Models
IWB
( ˚F )
71
67
MS09NW
63
71
67
MS12NN
63
71
67
MS15NN
63
71
67
MS17NN
63
Notes 1. I WB : Intake air wet-bulb temperature.
TC : Total Capacity (x10
TPC : Total Power Consumption (kW)
2. SHC is based on 80˚F of indoor intake air DB temperature.
2) COOLING CAPACITY CORRECTIONS
Refrigerant piping length ( one way )
Models
25ft (std)
1.0
MS09NW
1.0
MS12NN
1.0
MS15NN
1.0
MS17NN
75
TC
SHC
TPC
TC
10.4
5.9
0.75
9.7
9.9
6.9
0.71
9.2
9.3
7.7
0.67
8.6
15.4
11.6
1.01
14.4
14.6
10.4
0.95
13.6
13.7
8.9
0.90
12.7
17.9
9.2
1.25
16.7
16.9
11.0
1.18
15.8
15.9
12.5
1.12
14.7
19.7
10.2
1.42
18.4
18.7
12.1
1.34
17.4
17.5
13.7
1.28
16.3
3
Btu/h), SHC : Sensible Heat Capacity (x10
40ft
49ft
0.954
0.927
0.954
0.927
0.954
0.927
0.954
0.927
Outdoor intake air DB temperature ( ˚F )
85
95
SHC
TPC
TC
SHC
TPC
5.5
0.82
9.1
5.2
0.88
6.4
0.78
8.5
6.0
0.84
7.2
0.74
8.0
6.7
0.80
8.3
1.10
13.5
7.8
1.19
9.7
1.05
12.6
8.9
1.13
10.7
1.00
11.8
10.0
1.08
8.6
1.37
15.7
8.1
1.47
10.2
1.30
14.6
9.5
1.40
11.6
1.24
13.7
10.8
1.34
9.5
1.56
17.3
8.9
1.68
11.3
1.48
16.1
10.5
1.60
12.7
1.42
15.1
11.9
1.53
3
Btu/h)
105
115
TC
SHC
TPC
TC
SHC
8.5
4.8
0.93
7.8
7.9
5.5
0.89
7.3
7.3
6.1
0.86
6.6
12.6
7.3
1.25
11.6
11.7
8.3
1.20
10.8
10.8
9.1
1.15
9.8
14.6
7.5
1.55
13.4
13.6
8.8
1.48
12.5
12.5
9.8
1.43
11.4
16.1
8.3
1.77
14.8
15.0
9.7
1.70
13.8
13.8
10.8
1.63
12.6
TPC
4.4
0.97
5.1
0.93
5.5
0.89
6.7
1.30
7.6
1.25
8.3
1.20
6.9
1.61
8.1
1.55
8.9
1.48
7.7
1.84
8.9
1.78
9.8
1.70
9