Mitsubishi MS09NW Service Manual page 40

Split-type air conditioners
Hide thumbs Also See for MS09NW:
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the electrical box
(1) Remove the front panel. (Refer to 1)
(2) Remove the electrical cover.
(3) Disconnect the connector of the indoor coil thermistor.
(4) Disconnect the motor connector (CN211) and the vane
motor connector (CN151) on the electronic control P.C.
board.
(5) Unhook the catches (both upper and lower), remove the
electrical box.
4. Removing the vane motor
(1) Remove the front panel.
(2) Remove the screw of the vane motor, disconnect the con-
nector.
(3) Remove the vane motor.
5. Removing the line flow fan and the indoor fan motor
(1) Remove the front panel. (Refer to 1)
(2) Disconnect the connector from the vane motor.
(3) Pull out the drain hose from the nozzle assembly, remove
the nozzle assembly.
(4) Lifting the left side of the heat exchanger, remove the elec-
trical box.
(5) Remove the fixture of the fan motor.
(6) Remove the line flow fan and the fan motor.
40
PHOTOS
Photo 3
Vane motor screw
Vane motor
Photo 4
Fan motor
catches
Fan motor
fixture
Drain hose
Indoor coil
thermistor