Mitsubishi MS09NW Service Manual page 46

Split-type air conditioners
Hide thumbs Also See for MS09NW:
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1)
(2) Disconnect the connector and remove the clamp of fan
motor lead wire.
(3) Remove the propeller nut and remove the propeller fan.
(4) Remove screws securing the fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1)
(2) Remove the soundproof felt.
(3) Remove the terminal cover on the compressor
(4) Disconnect lead wires from the glass terminal of the com-
pressor.(Refer to 2)
(5) Release gas from the refrigerant circuit.
(6) Disconnect the welded part of the discharge pipe.
(7) Disconnect the welded part of the suction pipe.
(8) Remove nuts securing the compressor.
(9) Remove the compressor.
NOTE
Reclaim all refrigerant in an environmentally acceptable
manner.
46
PHOTOS
Photo 4
Propeller fan
Propeller fan nut
Photo 5
Discharge
pipe
Compressor
Compressor nuts
Clamp
Connector
Soundproof felt
Suction
pipe