Upflow Model Installed Vertically; Drain Exiting Right Side; General Drain Information; Field Supplied Drain - Goodman xMEC96 Series User Manual

Upflow / horizontal two-stage gas furnace
Table of Contents

Advertisement

G
D
I
ENERAL
RAIN
NFORMATION
All furnace models come with a factory installed drain trap. For
vertical installations, the trap will remain in the factory posi-
tion. All furnace models installed horizontally require the trap to
be relocated. Many drain hoses have a built–in grommet which
will provide a cabinet seal when installed. See instructions below
for your model and installation position. NOTE: Both sides of
the drain trap must be primed prior to initial furnace start
up
F
S
D
IELD
UPPLIED
RAIN
Drain the furnace and air conditioning coil if applicable, in com-
pliance with code requirements. In horizontal installations, a field
installed rubber coupling will allow the drain trap to be removed
for cleaning. The drain trap must be primed before initial fur-
nace start up. When an air conditioning coil drain is connected
to the field supplied furnace drain, it must be vented with an
open tee installed at a height no higher than the bottom of the
furnace collector box to prevent air conditioning condensate from
backing up into the furnace if the common drain became blocked.
U
M
I
PFLOW
ODEL
NSTALLED
The trap and factory installed hoses remain as shipped. The
furnace drain may exit either the right or left side of the fur-
nace cabinet.
D
E
R
S
RAIN
XITING
IGHT
IDE
1. Locate and Install the 45º pipe / hose drain coupling from
the outside of the cabinet (barbed end goes in the cabinet)
through hole in the right side of the cabinet and secure
with two field supplied #8 self-tapping screws (see Figure
21).
2. Locate the long drain hose #3 and cut at line "A" .
3. Install large end of hose #3 to trap outlet and secure with
1.25" clamp.
4. Install smaller end of hose #3 on 45º elbow and secure with
1" clamp.
5. Refer to Field Supplied Drain section for instructions on
field supplied / installed drain on outlet of furnace trap.
V
ERTICALLY
#1
#4
#7
#9
NOTE: Hoses are model specific
and not all hoses will be shipped with all models.
45 degree
barb-pipe
adapter
Installer selects right or left side drain
and installs this hose accordingly.
19
#2
#5
#8
#10
100 Degree
Elbow
#11
Figure 20
Figure 21
Coupling
Hose #1
Hose #2
45 degree
barb-pipe
adapter