REPLACEMENT BLOWER INSTALLATION

20
FIGURE 44
THERMODISC
1. Turn off the electrical power and the gas supply to the
stove.
2. Open the lower louvre control door, the two side doors,
and the fire viewing door. Remove the logs.
3. Remove the relief door held on with 6 screws. Discard
the gasket.
4. Disconnect the two blower wires. Remove the blower
bracket held on with 4 screws.
WS-415-098 / 04.11.00
RELIEF DOOR
FIGURE 45
VARIABLE
SPEED
SWITCH
RELIEF DOOR GASKET
TWIN BLOWER
5. Replace the blower using the existing bracket. When
connecting the replacement blower, tighten the screws with-
out distorting the rubber grommets. Replace the bracket/
blower assembly on the unit.
6. Reconnect the two wires. Hold the replacement gasket
in place and reattach the relief door body. Replace the logs.
Close all doors.
7. Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 15-30 min-
utes after lighting the stove and will run for approximately
30-45 minutes after the stove has been turned off. Use
of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings caus-
ing irreparable damage and must be prevented from com-
ing into contact with the blower or its compartment. Any
damage resulting from this condition is not covered by
the warranty policy.