Scale Calibration Procedure (lbs. or kg) with Remote Display
4.
Enter full service access mode. Power down the unit if necessary. Press
and hold down the Calibration push button then power up the scanner/scale.
Release the Calibration push button.
5.
Enter calibration mode. The remote display will flash all of the characters
available (see illustration below). Press the right arrow button twice (►)(►)
while the display flashes all characters. The remote display should read
CAL 1.
6.
Reinstall the platter onto the scanner/scale. Check the platter to ensure that
it is seated properly and nothing is interfering with its freedom to move.
Figure 60. Entering Full Service Access Mode
Figure 61. Entering Full Service Access Mode