Proper Lifting Technique
On every Stratos model there are two lifting handles located under the removable
platter. These handles are provided to assist in installation when placing the unit
in the checkstand cutout.
Figure 27. Lifting Handles
For MS2020 Units Only
When lifiting the unit with these handles it is important to rest your
thumbs against the front surface of the vertical window frame. If you do
not do this the unit will tilt toward you when it is lifted. This makes
installation difficult and increases the risk of dropping the scanner.
Figure 29. Rest Thumbs Against the Vertical Frame (MS2020 Shown)
26
U
NIT IN THE
(MS2021 Shown)
C
OUNTER
Figure 28. Rotate Handles Up