ELECTRICAL AND PERFORMANCE DATA

Input/Cabinet
Model
PS9A12N040UP11
PS9B12N060UP11
PS9B12N080UP11
PS9C16N080UP11
PS9C20N080UP11
PS9C16N100UP11
PS9C20N100UP11
PS9D20N120UP11
PS9D20N135UP11
Max. Outlet
Air Temp.
Model
PS9A12N040UP11
PS9B12N060UP11
PS9B12N080UP11
PS9C16N080UP11
PS9C20N080UP11
PS9C16N100UP11
PS9C20N100UP11
PS9D20N120UP11
PS9D20N135UP11
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
ROOM
FURNACE
THERMOSTAT
CONTROL
R
R
W
W
G
G
Y
Y/Y2
C
C
COMMON T'STAT CONNECTION
HEATING AND COOLING
THERMOSTAT CONNECTIONS
Unitary Products Group
Output
MBH
MBH
40
38
60
56
80
74
80
75
80
75
100
93
100
93
120
112
135
127
Nominal
Airflow
°F
CFM
165
1200
170
1200
175
1200
175
1600
170
2000
175
1600
170
2000
170
2000
175
2000
BLK
BLK (HOT)
WHT
WHT (NEUTRAL)
GRN
GRN
LINE WIRING CONNECTIONS
CONDENSING
UNIT
TO AIR CONDITIONER
CONTROLS
Blower Size
Blower
In.
HP
11 x 8
1/2
11 x 8
1/2
11 x 8
1/2
11 x 10
3/4
11 x 11
1
11 x 10
3/4
11 x 11
1
11 x 11
1
11 x 11
1
Cabinet
Total Unit
Width
In.
Amps
14-1/2
9
17-1/2
9
17-1/2
9
21
12
21
14
21
12
21
14
24-1/2
14
24-1/2
14
NOMINAL
120 VOLT
ROOM
THERMOSTAT
036-21578-002 Rev. B (0205)
Max.
Over-current
Amps
Protect
7.0
20
7.0
20
7.0
20
10.2
20
12.7
20
10.2
20
12.7
20
12.7
20
12.7
20
Min. Wire Size
AFUE
(awg) @ 75 ft.
Operating Weight
One Way
%
94.0
14
92.0
14
92.0
14
92.0
14
92.0
12
92.0
14
92.0
12
92.0
12
92.0
12
FURNACE
CONTROL
R
R
TO AIR CONDITIONER
W
W
CONTROLS
G
G
Y1
Y1
Y2
Y/Y2
C
C
COMMON T'STAT CONNECTION
HEATING AND TWO-STAGE COOLING
THERMOSTAT CONNECTIONS
Air Temp. Rise
°F
35 - 65
40 - 70
45 - 75
45 - 75
40 - 70
45 - 75
40 - 70
40 - 70
45 - 75
Approximate
121
135
142
157
159
162
164
180
180
CONDENSING
UNIT
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps9b12n060up11Ps9b12n080up11Ps9c16n080up11Ps9c20n080up11Ps9c16n100up11Ps9c20n100up11 ... Show all