Electrical And Performance Data - York AFFINITY PV9A12N040UP11 Technical Manual

Affinity pv9 series gas-fired condensing / high efficiency two stage variable upflow furnaces up to 94% afue natural gas 40 - 120 mbh input
Table of Contents

Advertisement

ELECTRICAL AND PERFORMANCE DATA

Input High/Low Output High/Low
Models
MBH
PV9A12N040UP11
40/26
60/39
PV9B12N060UP11
80/52
PV9B12N080UP11
PV9C16N080UP11
80/52
PV9C20N100UP11
100/65
120/78
PV9D20N120UP11
Max. Outlet
Air Temp.
Models
165
PV9A12N040UP11
PV9B12N060UP11
170
PV9B12N080UP11
175
PV9C16N080UP11
175
175
PV9C20N100UP11
PV9D20N120UP11
170
* ESP (External Static Pressure) .5" WC is at furnace outlet ahead of cooling coil.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
BLK
BLK (HOT)
WHT
WHT (NEUTRAL)
GRN
GRN
LINE WIRING CONNECTIONS
ROOM
THERMOSTAT
R
W1
W1/W
W2
G
Y1
Y2
C
TWO-STAGE HEATING AND TWO-STAGE COOLING
THERMOSTAT CONNECTIONS
Unitary Products Group
MBH
38/24
56/36
75/49
75/49
93/60
112/73
Nominal Airflow Cabinet Width Total Unit
°F
CFM
1200
1200
1200
1600
2000
2000
NOMINAL
120 VOLT
CONDENSING
FURNACE
UNIT
CONTROL
R
TO AIR CONDITIONER
CONTROLS
W2
G
Y1
Y/Y2
C
COMMON T'STAT CONNECTION
Blower Size
Blower
In.
HP
11 x 8
1/2
11 x 8
1/2
11 x 8
1/2
11 x 10
3/4
11 x 11
1
11 x 11
1
In.
Amps
14-1/2
9
17-1/2
9
17-1/2
9
21
12
21
14
24-1/2
14
ROOM
THERMOSTAT
R
W
G
Y
C
SINGLE STAGE HEATING
THERMOSTAT CONNECTIONS
ROOM
THERMOSTAT
R
W
G
Y1
Y2
C
SINGLE STAGE HEATING AND TWO-STAGE COOLING
THERMOSTAT CONNECTIONS
036-21584-001 Rev. C (0205)
Max.
Over-current
Amps
Protect
7.7
20
7.7
20
7.7
20
9.6
20
12.8
20
12.8
20
Min. Wire Size
AFUE
(awg) @ 75 ft.
Operating Weight
One Way
%
94.0
14
93.2
14
92.5
14
92.8
14
92.8
12
93.2
12
CONDENSING
FURNACE
UNIT
CONTROL
R
TO AIR CONDITIONER
W1/W
CONTROLS
G
Y/Y2
C
COMMON T'STAT CONNECTION
CONDENSING
FURNACE
UNIT
CONTROL
R
TO AIR CONDITIONER
W1/W
CONTROLS
G
Y1
Y/Y2
C
COMMON T'STAT CONNECTION
Air Temp. Rise
°F
35 - 65
40 - 70
45 - 75
45 - 75
45 - 75
40 - 70
Approximate
121
135
142
157
164
180
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Affinity pv9b12n060up11Affinity pv9b12n080up11Affinity pv9c16n080up11Affinity pv9c20n100up11Affinity pv9d20n120up11

Table of Contents