GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW / HORIZONTAL
MODULATING FURNACES
WITH ECM MOTOR
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
• Provides increased comfort level & very quiet unit opera-
tion
• Compact, easy to install, ideal height 40" cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• High velocity filter available for easy field installation.
• May be installed as either two-pipe (direct vent) or single
pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• ECM High-efficiency, direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
• Timed on, adjustable off blower capability for maximum
comfort.
• Independent door removal for greater durabilty and ease
of access.
• Easy access from front of unit for cleaning, maintenance or
service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• 3-way transition facilitates fresh air piping.
246815-YTG-D-0108

Advertisement

loading

Summary of Contents for York PC9*DH

  • Page 1 CERTIFIED Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.gamanet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2 246815-YTG-D-0108 22-3/4 13-7/8 HORIZONTAL CONDENSATE DRAIN OPENING 2” JUNCTION BOX HOLE 7/8” GAS PIPE ENTRY 1-1/2” CONDENSATE DRAIN HOLE 7/8” SIDE PIPING HOLE 3-3/8” 2-1/4 22-1/4 25-3/8 26-1/2 27-1/8 30-1/8 LEFT SIDE 1-1/4 DIMENSIONS Models PC9B12N060DH11 1200 PC9B12N080DH11 1200 PC9C16N080DH11 1600 PC9C16N100DH11 1600...
  • Page 3 AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM PC9B12N060DH11 High 1330 1130 1220 1040 1120 PC9C16N080DH11 PC9C16N100DH11 High 1660 1110 1550 1050 1610 1070 1440 1470 1370 1290 1130 1230 1050 1110 PC9D20N120DH11 High 2280 1510 1860 1190 2090...
  • Page 4 246815-YTG-D-0108 FILTER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- ter being used or select an appropriate value from the “Filter Performance”...
  • Page 5 For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available on-line at www.upgnet.com in the Product Catalog Section. AC 26A Two Stage Air Conditioner – Variable Speed Modulating Furnace THERMOSTAT THERMOSTAT *DN22U00124 *PP32U70124 24 – Volt Common 24 –...
  • Page 6 246815-YTG-D-0108 AC 26B Two Stage Air Conditioner – Variable Speed Modulating Furnace THERMOSTAT THERMOSTAT *DN22C00124 *DP22U70124 24 – Volt Common 24 – Volt Common First Stage Compressor First Stage Compressor 24 – Volt Hot 24 – Volt Hot E/W1 First Stage Heat First Stage Heat Second Stage Heat Second Stage Heat...
  • Page 7 AC 26C Two Stage Air Conditioner – Variable Speed Modulating Furnace THERMOSTAT *PP32U71124 *PP32U72124 24 – Volt Common First Stage Compressor 24 – Volt Hot E/W1 First Stage Heat Second Stage Heat Malfunction Light Second Stage Compressor Dehumidification Humidistat Step 1 of Thermostat User Configuration Menu must be set to MLTISTG Step 16 of Thermostat...
  • Page 8 246815-YTG-D-0108 HP 28A Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) THERMOSTAT *PP32U71124 *PP32U72124 24 – Volt Common First Stage Compressor 24 – Volt Hot Second Stage Aux. Heat Reversing Valve Energized in Cool Malfunction Light Second Stage Compressor E/W1...
  • Page 9 HP 28C Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) THERMOSTAT THERMOSTAT *DN22H00124 *PP32U70124 *DP22U70124 24 – Volt Common 24 – Volt Common First Stage Compressor First Stage Compressor 24 – Volt Hot 24 – Volt Hot (Heat XFMR) Emergency Heat Second Stage Aux.
  • Page 10 246815-YTG-D-0108 ACCESSORIES PROPANE (LP) CONVERSION KIT - 1NP0680 - All units This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. CONCENTRIC VENT TERMINATION - 1CT0302 (2") 1CT0303 (3") CONDENSATE NEUTRALIZER KIT - 1HT0901...
  • Page 11 246815-YTG-D-0108 NOTES Unitary Products Group...
  • Page 12 Subject to change without notice. Printed in U.S.A. Copyright © by Unitary Products Group. 2008. All rights reserved. Unitary Products Group NOTES 5005 York Drive 246815-YTG-D-0108 Supersedes: 246815-YTG-C-0606 Norman 73069...