TECHNICAL GUIDE
AFFINITY
MODELS: PC9*UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW MODULATING FURNACES
WITH ECM MOTORS
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
• Provides increased comfort level & very quiet unit opera-
tion
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• May be installed as either two-pipe (direct vent) or single
pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• ECM high efficiency direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance
or service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
246813-YTG-C-0606

Advertisement

Table of Contents
loading

Summary of Contents for York PC9B12N060UP11

  • Page 1 • Protection from intake, exhaust or condensate blockage. Visit us on the web at www.york.com for the most • Insulated blower compartment for quiet operation. up-to-date technical information. Additional rating information can be found at www.gamanet.org.
  • Page 2: Combustion Air Supply And Vent Piping

    24-7/16 BOTTOM IMAGE TOP IMAGE RETURN END SUPPLY END DIMENSIONS Cabinet Dimension Nominal Cabinet Models Size A (in.) B (in.) C (in.) D (in.) PC9B12N060UP11 1200 17-1/2 16-1/4 15-1/8 8-1/2 PC9B12N080UP11 1200 17-1/2 16-1/4 15-1/8 8-1/2 PC9C16N080UP11 1600 19-3/4 18-1/2...
  • Page 3: Electrical And Performance Data

    Blower Size Blower Max/Min Max/Min Maximum Input Minimum Input Models Over-current Protect Amps °F °F PC9B12N060UP11 60/21 57/20 11 x 8 40 - 70 20 - 50 PC9B12N080UP11 80/28 76/26 11 x 8 40 - 70 20 - 50 PC9C16N080UP11...
  • Page 4 246813-YTG-C-0606 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. THERMOSTAT CHART - TWO STAGE HP Unitary Products Group...
  • Page 5 246813-YTG-C-0606 THERMOSTAT CHART - TWO STAGE AC Unitary Products Group...
  • Page 6: Air Flow Data

    246813-YTG-C-0606 AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM PC9B12N060UP11 PC9B12N080UP11 JUMPER SETTINGS m³/min m³/min High High High High COOL Tap ADJ Tap 1330 37.7 25.5 1310 37.1 25.2 1130 32.0 22.7 1100 31.2 21.0 1220 34.6...
  • Page 7: Filter Performance - Pressure Drop Inches W.c. And (Kpa)

    246813-YTG-C-0606 FILTER PERFORMANCE NOTE: The filter pressure drop values in the “Filter Perfor- mance” table shown are typical values for the type of filter The airflow capacity data published in the “Blower Perfor- listed and should only be used as a guideline. Actual pres- mance”...
  • Page 8 SIDE RETURN FILTER - 1SR0402 - All Models 1SR0200 - All Models Subject to change without notice. Printed in U.S.A. 246813-YTG-C-0606 Copyright © by York International Corp. 2006. All rights reserved. Supersedes: 246813/036-21669-001 Rev. B (0406) Unitary 5005 Norman Products...