Delivered Condition - Viessmann VITOGAS Technical Manual

Low temperature gas boiler 11 to 60 kw
Table of Contents

Advertisement

DHW cylinder
(cont.)
Pressure drop (primary circuit)
1000
800
600
500
400
300
200
100
80
60
50
40
30
20
10
8
6
5
4
3
Heating water throughput in litres/h
of one cylinder cell.
A 160 litre cylinder capacity
B 200 litre cylinder capacity

Delivered condition

Vitocell 300-H, type EHA, 160 and 200 litre capacity
DHW cylinders made from high-alloy stainless steel.
– fitted thermal insulation made from rigid polyurethane foam
– integral welded sensor well for cylinder temperature sensor or control
thermostat
– integral thermometer and
– threaded adjustable feet
Colour of the epoxy-coated sheet steel casing: Vitosilver.
VITOGAS
C 350 litre cylinder capacity
D 500 litre cylinder capacity
Pressure drop on the DHW side
D
C
20
B
10
A
9
8
7
6
5
4
3
2
1
500 700 900
600 800
DHW throughput in l/h
of one cylinder cell.
A 160 and 200 litre cylinder capacity
B 350 and 500 litre cylinder capacity
Vitocell 300-H, type EHA, 350 and 500 litre capacity
DHW cylinders made from high-alloy stainless steel.
– with fitted thermal insulation made from rigid polyurethane foam
– Connectors for cylinder temperature sensor or control thermostat
– integral thermometer and
– threaded adjustable feet.
Packed separately and fitted to the crate:
– Female reducer R 1 × ½"
– sensor well and
– thermal insulation piece for the sensor well
Colour of the epoxy-coated sheet steel casing: Vitosilver.
2000
4000
1000
3000
5000
VIESMANN
A
B
3
33

Advertisement

Table of Contents
loading

Table of Contents