Resetting Codes To Their Delivered Condition - Viessmann Vitopend 200-W Installation And Service Instructions For Contractors

Gas fired combi boiler for balanced flue operation natural gas and lpg version
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
FA:20
Raising the set boiler
water temperature or
the set flow temperature
when changing from op-
eration with reduced
room temperature to op-
eration with standard
room temperature by
20 %. See example on
page 110 (only for
weather-compensated
control units).
Fb:30
Duration for raising the
set boiler water tem-
perature or the set flow
temperature (see cod-
ing address "FA")
60 min. See example on
page 110 (only for
weather-compensated
control units).

Resetting codes to their delivered condition

Press the following keys:
1. L + G simultaneously for
approx. 2 s.
2. e
"Standard setting?
Yes" appears.
70
Possible change
FA:0
Temperature rise adjusta-
to
ble from 0 to 50 %
FA:50
Fb:0
Duration adjustable from
to
0 to 300 min;
Fb:150
1 step
3. d
to confirm
or
4. a/b
to select "Standard set-
ting? No".
2 min