VIESMANN VITOGAS Low temperature gas boiler 11 to 60 kW Technical guide VITOGAS 200-F VITOGAS 100-F Type GS2 Type GS1D Low temperature gas boilers, 11 to 60 kW Low temperature gas boilers, 29 to 60 kW For modulating boiler water temperature For modulating boiler water temperature ■...
4. 3 Boiler accessories ....................... 44 ■ Four-way mixer ....................... 44 ■ Safety equipment block ................... 44 ■ Plinth for Vitogas 200-F ..................44 ■ Plinth for Vitogas 100-F ..................44 ■ Flue gas monitoring sensor ..................45 Design information 5.
Page 3
■ Functions in connection with the function extension 0 – 10 V (accessory) ..... 61 ■ External extension H5 ..................... 61 ■ Vitocom 100, type GSM ..................62 ■ Control module V ....................62 Keyword index .............................. 63 VIESMANN VITOGAS...
D Digital Vitotronic boiler control unit Delivered condition ■ Boiler with fitted thermal insulation and atmospheric premix burner ■ 1 product pack (boiler coding card and Vitogas 200-F technical doc- for natural gas and LPG according to DVGW Code of Practice G 260 umentation) [Germany] or local regulations ■...
Installation of an efficient return tempera- (minimum value) ture raising facility (e.g. through 4-way mixer and minimum limit and/or return temperature raising pump) Low-end boiler water temperature 35 ºC Through the Viessmann control unit (also for frost protection) (standard delivery) VIESMANN VITOGAS...
Required draught mbar 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 Flue gas connection Ø mm Seasonal efficiency [to DIN] 84 (H )/93 (H = 75/60 °C Standby heat loss at 60 °C boiler water temperature VIESMANN VITOGAS...
Page 7
If the gas supply pressure exceeds the maximum permitted value, install a separate gas pressure governor upstream of the system. A Subframe (accessory) KV Boiler flow Drain and diaphragm expansion vessel SSI Draught hood SV Safety flow GA Gas connection KR Boiler return Dimensions Rated output 1076 1130 1012 1012 1012 1082 1082 VIESMANN VITOGAS...
Page 8
Drain and diaphragm expansion vessel Pressure drop (primary circuit) The Vitogas 200-F is only suitable for fully pumped hot water heating C Rated output 29 kW systems. D Rated output 35 and 42 kW...
■ Avoid very dusty conditions bons may occur, install the boiler only if adequate measures can be ■ Avoid high levels of humidity taken to provide a supply of uncontaminated combustion air. ■ Prevent freezing and ensure good ventilation VIESMANN VITOGAS...
D Digital Vitotronic boiler control unit Delivered condition ■ Boiler with fitted thermal insulation and atmospheric premix burner ■ 1 product pack (boiler coding card and Vitogas 100-F technical doc- for natural gas and LPG according to DVGW Code of Practice G 260 umentation) or local regulations ■...
Installation of an efficient return tempera- (minimum value) ture raising facility (e.g. through 4-way mixer and minimum limit and/or return temperature raising pump) Low-end boiler water temperature 35 ºC Through the Viessmann control unit (also for frost protection) (standard delivery) VIESMANN VITOGAS...
Vitogas 100-F (cont.) 2.3 Specification Gas boiler, type B , category II 11 BS 2ELL3 P Rated output Rated heat input 32.0 38.6 46.4 53.0 66.2 Heating surface 1.99 2.46 2.93 3.40 4.35 U-value of thermal insulation 0.45 0.45 0.45 0.45...
Page 13
Vitogas 100-F (cont.) Note If the gas supply pressure exceeds the maximum permitted value, install a separate gas pressure governor upstream of the system. A Subframe (accessory) KR Boiler return Drain and diaphragm expansion vessel KV Boiler flow SSI Draught hood...
C Rated output 48 and 60 kW KV Boiler flow SSI Draught hood Pressure drop (primary circuit) The Vitogas 100-F is only suitable for fully pumped hot water heating systems. Installation Minimum clearances Observe the given dimensions to ensure easy installation and maintenance.
Page 15
Vitogas 100-F (cont.) Installation Otherwise, the system may suffer faults and damage. ■ Avoid air contamination through halogenated hydrocarbons (e.g. as In rooms where air contamination through halogenated hydrocar- in sprays, paints, solvents and cleaning agents) bons may occur, install the boiler only if adequate measures can be ■...
Listed below are the specifications of the DHW cylinders that require For DHW cylinders with a cylinder capacity greater than 500 l, cylinder system connections to the boiler (see Viessmann pricelist). banks and further DHW cylinders from the Viessmann pricelist, the connecting lines must be set on site. VIESMANN...
Information regarding continuous output When designing the system for continuous output as stated or calcu- lated, allow for the corresponding circulation pump. The stated con- ≥ contin- tinuous output is only achieved when the rated boiler output uous output. VIESMANN VITOGAS...
Page 18
300 litre capacity HV/SPR BÖ KW/E BÖ Inspection and cleaning aperture SPR Cylinder temperature sensor of the cylinder temperature control Drain or the control thermostat Heating water return Protective magnesium anode Heating water flow WW DHW Cold water DHW circulation VIESMANN VITOGAS...
Page 19
SPR Cylinder temperature sensor of the cylinder temperature control Drain or the control thermostat Heating water return Protective magnesium anode Heating water flow WW DHW Cold water DHW circulation Capacity Length (7) Width Height 1955 1784 1230 7 100 excl. thermal insulation 7 650 VIESMANN VITOGAS...
Page 20
Standard values for → 1.0 × N ■ T = 60 °C → 0.75 × N ■ T = 55 °C → 0.55 × N ■ T = 50 °C → 0.3 × N ■ T = 45 °C VIESMANN VITOGAS...
Page 21
DHW cylinder is made available at the respective heating water flow temperature and when heating DHW from 10 to 60 °C. Capacity 1000 Heat-up time (min.) at a heating water flow tempera- ture of 90 °C 80 °C 70 °C VIESMANN VITOGAS...
Information on continuous output When designing the system for continuous output as stated or calcu- lated, allow for the corresponding circulation pump. The stated con- ≥ contin- tinuous output is only achieved when the rated boiler output uous output. VIESMANN VITOGAS...
Page 24
Standard values for → 1.0 × N ■ T = 60 °C → 0.75 × N ■ T = 55 °C → 0.55 × N ■ T = 50 °C → 0.3 × N ■ T = 45 °C VIESMANN VITOGAS...
Page 25
DHW cylinder is made available at the respective flow temper- ature and when heating the DHW from 10 to 60 °C. Cylinder capacity Heat-up time (min) at heating water flow temperature 90 °C 80 °C 70 °C VIESMANN VITOGAS...
The DHW side of the DHW cylinder is made from high-alloy stainless white. steel with fitted rigid polyurethane foam thermal insulation. ■ Integral welded sensor well for cylinder temperature sensor or con- trol thermostat ■ Integral thermometer ■ Threaded adjustable feet VIESMANN VITOGAS...
BÖ Ø 64 BÖ Inspection and cleaning aperture Sensor well for cylinder temperature sensor or control thermo- Heating water return stat Heating water flow Protective magnesium anode KW Cold water VIESMANN VITOGAS...
Page 28
Max. draw-off rate (l/min) at heating water flow temperature 90 °C 80 °C 70 °C Available water volume Cylinder volume heated to 60 °C Without booster Cylinder capacity Draw-off rate l/min Available water volume Water with t = 60 °C (constant) VIESMANN VITOGAS...
■ integral protective magnesium anode ■ fitted thermal insulation made from rigid polyurethane foam ■ integral welded sensor well for cylinder temperature sensor or control thermostat and ■ threaded adjustable feet Colour of the epoxy-coated sheet steel casing: Vitosilver. VIESMANN VITOGAS...
500 litre: Where access to the boiler room is difficult, removal of the casing leaves the DHW cylinder with only the dimensions given in the table. VIESMANN VITOGAS...
Page 31
Heating water flow WW DHW Cold water DHW circulation Dimensions Note When installing the sensor well and cylinder temperature sensor, Cylinder capacity litres maintain a minimum distance of 450 mm behind the DHW cylinder. 1256 1320 1397 1461 1590 1654 VIESMANN VITOGAS...
Page 32
DHW cylinder being made available at the relevant flow temperature and when DHW is heated from 10 to 60 °C. Cylinder capacity litres Heat-up time (minutes) at heating water flow temperature 90 °C 80 °C 70 °C VIESMANN VITOGAS...
Packed separately and fitted to the crate: Colour of the epoxy-coated sheet steel casing: Vitosilver. – Female reducer R 1 × ½" – sensor well and – thermal insulation piece for the sensor well Colour of the epoxy-coated sheet steel casing: Vitosilver. VIESMANN VITOGAS...
Information on drinking water filter According to DIN 1988-2, a drinking water filter should be installed in systems with metal pipework. Viessmann and DIN 1988 also recom- mend the installation of a drinking water filter when using plastic pipes, to prevent contamination entering the DHW system.
■ Low electricity costs and precise control characteristics through the ■ Also available as kit. For further details, see the Viessmann pricelist. use of high efficiency pumps and optimised mixer curve. ■ Also available with staged pumps.
Page 36
Installation accessories (cont.) For part no. in conjunction with the different circulation pumps, see Viessmann pricelist. The dimensions of the heating circuit distributor are the same, with or without mixer. Heating circuit connec- ¾ 1¼ tion Flow rate (max.) a (female) ¾...
Page 37
B Ball valves with thermometer (as programming unit) C Circulation pump D Ball valve Installation example: Divicon with triple manifold Dimensions Manifold with heating circuit connection R ¾ and R 1 R 1¼ G 1¼ (shown without thermal insulation) HR Heating return HV Heating flow VIESMANN VITOGAS...
Page 38
■ with R 1 = 1.5 m Note For further components (pipe assembly, distributor, etc.) determine the ■ with R 1¼ = 2.5 m pressure drop and deduct it from the residual head. Example: Flow rate ´ = 0.665 m VIESMANN VITOGAS...
Page 39
A Divicon R ¾ with mixer D Divicon R ¾, R 1 and R 1¼ without mixer B Divicon R 1 with mixer C Divicon R 1¼ with mixer D Divicon R ¾, R 1 and R 1¼ without mixer VIESMANN VITOGAS...
Page 40
Operating mode: Constant differential pressure Pump rate in m³/h A Divicon R ¾ with mixer C Divicon R 1¼ with mixer B Divicon R 1 with mixer D Divicon R ¾, R 1 and R 1¼ without mixer VIESMANN VITOGAS...
Page 41
Part no. 7429 739: R 1 Part no. 7429 740: R 1¼ Only with manually controlled heating circuit pumps. Fitted onto the Divicon. Pump rate in m³/h A Divicon R ¾ with mixer B Divicon R 1 with mixer VIESMANN VITOGAS...
Page 42
A Connection option for expansion vessel HV Heating water flow HR Heating water return Part no. 7466 337 for Divicon R 1¼ Rp ¾ A Connection option for expansion vessel HV Heating water flow HR Heating water return VIESMANN VITOGAS...
Page 43
Wall mounting bracket Part no. 7465 894 Part no. 7465 439 for individual Divicon for manifold With screws and dowels. With screws and dowels. for Divicon with mixer without mixer for Divicon R ¾ and R 1 R 1¼ VIESMANN VITOGAS...
■ with automatic air vent valve with automatic shut-off facility Part no. 7143 780 for 50 and 63 kW ■ incl. thermal insulation Plinth for Vitogas 200-F Height: 250 mm ■ Part no. 7196 461 for 11 to 22 kW ■...
Observe the requirements of DIN 18560-2 [or local regulations]. a water content > 15 l/kW. 5.7 Plastic pipework for radiators We also recommend the installation of a temperature limiter to limit the maximum temperature of plastic pipes in heating circuits with radia- tors. VIESMANN VITOGAS...
5.10 Low water indicator According to the EN 12828, special low water level protection can be Viessmann Vitogas are equipped with type-tested thermostats and omitted for boilers up to 300 kW, as long as heating can be reliably high limit safety cut-outs. Tests have verified that the burner will be prevented when the water level is too low.
■ Via control module V (accessory): – External heating program changeover – Demand with set default value – Blocking the boiler – Short term operation of DHW circulation pump – Fault message input and fault message output VIESMANN VITOGAS...
1.6 m, fully wired IP rating IP 32 to EN 60529; ensure through appropriate design and installation Sensor type Viessmann Pt500 Permissible ambient temperature – during operation 0 to +130 °C – during storage and transport -20 to +70 °C...
4(2) A, 230 V~ gramming for reduced operation must be installed downstream of the – Burner plug fA 4(2) A, 230 V~ boiler (see Viessmann pricelist register 18 "Heating circuit control – Total max. 6 A, 230 V~ units"). Delivered condition ■...
Heating circuit pump 4(2) A 230 V~ boiler (see Viessmann pricelist register 18 "Heating circuit control Circulation pump for cylinder heat- 4(2) A 230 V~ units"). Total sÖ, sA max.
■ High limit safety cut-out – Program selection DIN STB 106005 – Holiday program – Party and economy mode DIN STB 98108 – DHW temperature – Heating curves for boiler water temperature and flow temperature DIN STB 116907 – Time / Date VIESMANN VITOGAS...
Page 52
IP 20 D to EN 60529; keys: ensure through appro- ■ Heating and DHW priate design/installa- ■ Only DHW tion ■ Standby mode Function Type 1B to External heating program changeover via control module V. EN 60 730-1 Summer mode ("DHW only") VIESMANN VITOGAS...
4 A, 230 V~ Burner 4(2) A, 230 V~ lÖ Burner, two-stage Only with auxiliary module (part of the standard delivery for Viessmann boil- ers) 1(0.5) A,230 V~ Total max. 6 A, 230 V~ Delivered condition ■ Programming unit Heating system with heating circuit with mixer ■...
Page 54
Only with auxiliary module (part of the ■ The frost protection function is stopped when the outside tempera- standard delivery for Viessmann boil- ture rises above approx. +3 °C, i.e. the heating circuit pump and ers) 1(0.5) A,230 V~ burner will be switched off.
Permissible ambient temperature tact temperature sensor) – during operation 0 to +40 °C The mixer motor is mounted directly onto the Viessmann mixer DN 20 – during storage and transport -20 to +65 °C to 50 and R ½ to 1¼.
IP 32 to EN 60529; ensure through appropriate design Specification and installation Lead length 3.5 m, fully wired Sensor type Viessmann Ni500 Rated voltage 230 V~ Permissible ambient temperature Rated frequency 50 Hz – during operation 0 to +120 °C Power consumption –...
Rated breaking capacity of the zero volt contact – max. 6(1) A, 230 V~ – min. 1 mA, 5 V– IP rating IP 20 to EN 60529; ensure through appropriate design/installation Function RS Type 1B to EN 60730-1 VIESMANN VITOGAS...
RS function must only affect the heating circuit with mixer. Information regarding the Vitotrol 200 and 300 For every heating circuit in a heating system, one Vitotrol 200 or one Vitotrol 300 can be deployed. VIESMANN VITOGAS...
– during storage and transport -20 to +65 °C Set room temperature range – for standard mode 10 to 30 °C adjustable to 3 to 23 °C or 17 to 37 °C – for reduced mode 3 to 37 °C VIESMANN VITOGAS...
1.5 times the flue pipe diameter, measured from the boiler edge (back) to the chimney stack. ■ Condensing boilers with Viessmann balanced flue system: Order the balanced flue pipe with connector for the flue gas temper- ature sensor separately.
Cable 2.0 m long with plugs "X12" and fA for connection to the control design and installation Permissible ambient temperature unit. – during operation 0 to +40 °C – during storage and transport -20 to +65 °C VIESMANN VITOGAS...
■ With contract SIM card for the operation of the Vitocom 100 via mobile phone Part no. Z004615 Note For further information regarding the conditions of contract, see the Viessmann pricelist. Specification Rated voltage 230 V ~ Functions: Rated frequency 50 Hz ■...