Advertisement

4-3. Indoor Unit (RAS-24NKD-E5,RAS-24NKDX5,
RAS-18NKD-E5, RAS-18NKDX5)
No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro Power Module (M01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor
13
Relay : (RY04)

4-4. Outdoor Unit (RAS-24NA-E, RAS-24N2AX)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
AFS-220-31A
———
µRM1260V
TMP87CM40AN
———
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
BET6.3A
15G561K
RF-2TK5R6
MP35EA12
G5NB-1A
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
PH400X3CS-4KT1 Winding resistance (Ω )
(at 20 °C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 − 240 V, 50 Hz
FG-240-42A
Winding resistance (Ω )
(at 20 °C)
AC 450 V, 3.0µF
451305L
AC 440 V, 50µF
RS44B506U0218S
220 − 240 V, 50 Hz
A35
– 13 –
FILE NO. SVM-06005
Specifications
AC 200 − 240V, 31W
10 kΩ at 25°C
DC 390 V, Secondary DC 12 V
10 kΩ at 25°C
27mH, 600mA
4 A, 600 V
4.7µF, 400 V
T6.3 A, 250 V
560 V
5.6Ω , 2 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Coil DC 12V, 16.7mA, Contact AC 250V, 1A
Specifications
C-R
1.13
Red-Black
128
C-S
2.10
White-Black
126