4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-18NKHD-E5)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro Power Module (M01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor

4-2. Outdoor Unit (RAS-18NAH-E)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74, R86)
11
Fuse (F01)
Type
AFS-220-31A
———
µRM1260V
TMP87CM40AN
———
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
BET6.3A
15G561K
RF-2TK5R6
MP35EA12
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH340X3C-4KT1 Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
FG-240-42A-1
Winding resistance (Ω)
(at 20°C)
451305L
AC 450 V, 3.0µF
RS44B506U0218S AC 440 V, 50µF
VHV (STF)
AC 220 – 240 V
TE / TD
10 kΩ at 25°C / 50 kΩ at 25°C
220 − 240 V, 50 Hz
CLK-26J
TT-05
220 – 240 V
TMP47C840N
15G471K
470 V
MT3
T6.3 A, 250 V
– 12 –
FILE NO. SVM-06005
Specifications
AC 200 − 240V, 31W
10 kΩ at 25°C
DC 390 V, Secondary DC 12 V
10 kΩ at 25°C
27mH, 600mA
4 A, 600 V
4.7µF, 400 V
T6.3 A, 250 V
560 V
5.6Ω , 2 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Specifications
C-R
1.46
Red-Black
128
C-S
2.47
White-Black
126