(1) Operation flow chat.
Case
In case of the first operation, after circuit breaker turns OFF/ON or after reset by case No. 4-1, 4-2, 8 and 9.
The Air-Purifier will operates after 1 hour.
1&2
For daily used, without turning OFF circuit breaker, Air-Purifier operates immediately.
By using short timer function of remote control*, Air-Purifier operates immediately.
3
In case of some error occurs within 1 minute, the above items need to be checked.
4-1
Case no 3, reset by [RESET] button on the indoor unit. Then Air-Purifier will operate again after 1 hour.
4-2
Case no 3, reset by [FILTER] button on the remote control. Then Air-Purifier will operate again after 1 hour.
4-3
Case no 3, reset by turning OFF the unit and turning ON again. Then Air-Purifier operates immediately.
In case of some error occurs after 1 minute. Air-Purifier will turn OFF but in contrast, PAP LED will keep turning
5
ON continuously.
6
Case no 5, the Air-Purifier will operate again after 10 minute.
After complete 500 hours operation, FILTER LED will turn ON and Air-Purifier will turn OFF. In addition, Air-Purifier
7
should be cleaned.
8
Case no 7, reset by [RESET] button on the indoor unit, and Air-Purifier will operate again after 1 hour.
9
Case no 7, reset by [FILTER] button on the remote control, and Air-Purifier will operate again after 1 hour.
!
Case no 7, can not reset by turning unit OFF and ON.
* Short timer is the function of the remote control that activates the setting for the sudden operation. This
function can be set as shown below.
1. Press [ ] button to turn the unit OFF.
2. Use the tip of the pencil to push the [CHECK] button and hold, "00" will show on display, then press [SET]
button to make "00" disappear.
3. Press [ ] button again to turn the unit ON.
4. When short timer is activated, all setting on the remote operates immediately, Besides, all LED turns ON
continuously for 2 seconds.
PAP
START
OPERATION LED ON
PAP LED ON
Less than 1 hour
Indoor fan ON
1
Air-Purlfier OFF
2
Air-Purlfier ON
Error after 1 minute
Operation confirm
5
PAP LED ON
No error
Air-Purifier OFF
PAP LED ON
Air-Purifier ON
6
10 minutes
500 hours
7
FILTER LED ON
Air-Purifier OFF
Reset by
8
1. [RESET] button
9
2. [FILTER] button
!
Descriptions
– 24 –
1 hour later
Error within 1 minute
3
FILTER LED ON
Air-Purifier OFF
Checking
Air-Purifier insertion
Inlet-Grlll assembly
Micro switch
Hi voltage unit
Reset by
1. [RESET] button
2. [FILTER] button
3. Turn unit OFF/ON
4-1 & 4-2
FILE NO. SVM-06005
4-3

Hide quick links: