4-5. Indoor Unit (RAS-13UKP-E4, RAS-10UKP-E4, RAS-07UKP-E4, RAS-13UKPX4,

RAS-10UKPX4, RAS-12UKPX4, RAS-07UKPX4)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Transformer
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB50)
8
Capacitor (C50)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Louver motor
12
Relay (Comp., RY01)

4-6. Outdoor Unit (RAS-13UA-E4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
Running capacitor
4
(for compressor)
Type
SKF- 220-20-4A-1
TT-10
TMP87CM40AN
*SS11V-06270
KBP06M/51
PF1E222MNN1625
BET6.3A
15G561K
MP24Z
DI1U
Type
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
PH225X2C-4FT
Winding resistance (W)
(at 20 C)
Output (Rated) 30 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
HF-240-30B
Winding resistance (W)
(at 20 C)
DS451155BPQC AC 450 V, 1.5µF
DS371356CPNB
AC 370 V, 35 F
- 20 -
Specifications
AC Motor with 150 C thermo fuse
W
°
10k at 25 C
°
W
10k at 25 C
27mH, 600mA
1.5A, 600 V
2200mF, 25 V
T6.3A, 250VAC
560 V
12VDC
Rating 25A/AC250 V, 3~48VDC
Specifications
°
°
m
FILE NO. SVM-05001
°
C-R
C-S
2.35
3.22
Red-Black
White-Black
245
388