• Clock Frequency

4.18.2 PTP Status

PTP is an acronym for Precision Time Protocol, a network protocol for synchronizing the clocks of computer systems. This page
allows the user to configure and inspect the current PTP clock settings.
The page includes the following fields:
Object
• One_pps_mode
• External Enable
• VCXO_Enable
• Clock Frequency
This will allow setting the Clock Frequency.
The possible range of values are 1 - 25000000 (1 - 25MHz)
Figure 4-18-2: PTP Clock configuration page screenshot
Description
Shows the current One_pps_mode configured.
1. Output : Enable the 1 pps clock output
2. Input : Enable the 1 pps clock input
3. Disable : Disable the 1 pps clock in/out-put
Shows the current External clock output configuration.
1. True : Enable the external clock output
2. False : Disable the external clock output
Shows the current VCXO rate adjustment configuration.
1. True : Enable the external VCXO rate adjustment
2. False : Disable the external VCXO rate adjustment
Shows the current clock frequency used by the External Clock.
The possible range of values are 1 - 25000000 (1 - 25MHz)