After this repair step
the core unit can be
pulled out of the plat-
form slightly (with still con-
nected hoses and wires).
Now the covers of the core
unit can be removed.
Use a pair of flat pli-
ers to pull off insulat-
ing sleeve with recep-
tacle.
The flat receptacle on
the ground wire has a
special connector
latching (see detail). Press
down lever at first, then pull
off receptacle.
68
R E P A I R S
41
•
Loosen 4 screws (41, oval shaped head) at the bottom side of platform.
For complete removal of the core unit proceed as follows:
•
Remove bottom cover (refer to page 48).
•
Disconnect both insulated faston receptacles (15).
•
If present, disconnect ground wire (15, part of thermoblock assembly).
•
If the thermoblock or core unit has to be replaced, disconnect milk frother connector
(61). Otherwise the core unit can be removed together with this connector (see page
64).
•
Remove water tank connector (53, see page 62).
Citiz service manual
53
15
61
55