1. The refrigerator must be level both directions
2. There sould be 20mm clearance to the wall
3. Ventilation must be provided as shown in
alternatives A,B,C or D
4. The ventilation duct must at least measure
105mm x the wtdth of the refrigerator
200cm²
5. Only the entire cooling unit must project into
the duct as shown
6 Air passing through the duct must not be
preheated by any source of heat
7. Ventilation grills, if used, must have openings
of at least 200cm² each