When operated, the electronic measures the temperature of the indoor air
sensor (NTC) and controls depending on this, the heating efficiency of the
absorber with the help of the HiPro-Electronic .
19.2
Self-test of the electronics
After switching on the supply voltage (Hardware- Reset) the software
carries out a selftest, in which the value of resistance of the NTC-sensors
(air-sensor, evaporator sensor) are measured.
In case the value of the resistance measuring is not corresponding
to the values of resistance fixed by the software, an error is
signalized.
Air-Sensor
The air-senosr is mark with
a red point!
Automatic fault analysis
19.3
The type of error is signalised through n flashing impulses of the inner
lighting (P_LIGHT) as well as REDDOT_LED with a frequency of 0.5 Hz, as
shown in the following table:
Type of error
general error electronic, power supply
everything OK / no poti connected
everything OK / poti connected
error NTC- Air-Sensor
error NTC- Evaporator-Sensor
error NTC- Air-Sensor + Evaporator Sensor
With the help of a reset you can see the fault signal (n) again.
In case an error is recognised (n>2), the temperature adjustment will not be
started, and the heating element will not be switched on.
The inner lighting and the Red-Dot will flash with ca. 4 Hz.
Evaporator-Sensor
Number of flashing impulses
28
n = 0
n = 1
n = 2
n = 3
n = 4
n = 5