Dometic RH 436D Manual

Dometic RH 436D Manual

Minibar
Hide thumbs Also See for RH 436D:

Advertisement

Quick Links

MANUAL
RH 436D
RH 447D
RH 430LD
RH 440LD
RH 441LD
RH 455LD
RH 456LD
RH 460LD
RH 461LD
RH 456LDE
English
Type H20 / 60
821 2693 -61
miniBar
T.D. 04/02

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RH 436D

  • Page 1 MANUAL miniBar RH 436D RH 447D RH 430LD RH 440LD RH 441LD RH 455LD RH 456LD RH 460LD RH 461LD RH 456LDE English Type H20 / 60 T.D. 04/02 821 2693 -61...
  • Page 2: Table Of Contents

    INTRODUCTION FOR YOUR SAFETY 2.1 Warnings and Safety Advice 3 2.2 Coolants WARRANTY AND CUSTOMER SERVICE INSTALLATION 4.1 The Purpose of this Manual 4.2 Tools/Materials Required 4.3 Unpacking 4.4 Cleaning 4.5 Installation 4.6 Securing 4.7 Connecting the Device to the Electricity Supply 4.8 Changing the Sliding Hinge 4.9 Changing the Doorhang...
  • Page 3: Introduction

    Any damage due to improper use is not covered by the warranty. The warranty does not cover any modifications to the appliance or the use of non-original Dometic parts; the warranty does not apply if the installation and operating instructions are not adhered to and no liability shall be entertained. Parts can be ordered throughout Europe from our Dometic Service department.
  • Page 4: Installation

    INSTALLATION The Purpose of this Manual The manual shows you how to: install the miniBar correctly. Ÿ operate the miniBar correctly. Ÿ guarantee the miniBar´s correct maintenance and functioning. Ÿ deal with faults by yourself. Ÿ Tools / Materials Required You will need the following tools for initial operation: mild detergent Unpacking...
  • Page 5: Installation

    Installation IMPORTANT: Please follow the installation details below carefully. Guarantee is valid for products installed as described only. 1. The refrigerator must be level both directions 2. There sould be 20mm clearance to the wall 3. Ventilation must be provided as shown in alternatives A,B,C or D 4.
  • Page 6: Securing

    Securing 4.6.1 RH456LD/E 1. Tighten screw. 2. Put on cap. 4.6.2 RH436D, RH447D, RH430LD, RH440LD, RH441LD, RH460LD, RH461LD The miniBar must be screwed onto the cupboard using the lower hinges. 1. Tighten screw. 2. Put on cap.
  • Page 7: Connecting The Device To The Electricity Supply

    If this is not the case, do not connect the device and contact your dealer! If the connection cable is damaged it must be replaced by the Customer Service at Dometic, or by respectively qualified personnel, in order to prevent any hazards. 4.7.1...
  • Page 8: Changing The Sliding Hinge

    If the plug supplied on the mains lead is not suitable for the socket in your home, it should be cut off and disposed of safely, or destroyed, to avoid any possible shock hazard resulting from the plug being inserted into a 13 amp socket elswhere in the use.
  • Page 9: Changing The Doorhang

    Changing the Doorhang ( RH436D, RH447D, RH430LD, RH440LD, RH441LD, RH460LD, RH461LD)
  • Page 10: Instruction For Use

    INSTRUCTION FOR USE Initial Operation The device must be plugged into a properly Ÿ earthed socket. The miniBar achieves its operating Ÿ temperature after several hours. The miniBar operates silently ! Temperature Control The miniBar is fitted with an electronic temperature control.
  • Page 11: Automatic Door Control (Adc)

    Automatic Door Control (ADC) The following descriptions only apply to devices with ADC. Using a red dot in the display window (A, point 3), the ADC shows that the miniBar´s door has been opened. 1. Open the miniBar, check its contents and - if applicable- stock it up again.
  • Page 12: Interior Light

    Changing bulbs: 1. Pull out the 2. Remove the 3. Remove defective mains plug. reflector disk. bulb. 4. Insert new bulb. 5. Clip reflector disk back in. To obtain spare bulbs, please contact your Dometic Service Centre.
  • Page 13: Environmental Advice

    Environmental Advice miniBars manufactured by Dometic GmbH are free from CFCs and fluorinated hydrocarbons. The cooling unit uses ammonia as the coolant (a natural compound of hydrogen and nitrogen). Cyclopentane, which does not damage the ozone layer, is used as propellant for the insulation made from PU-foam.
  • Page 14: Check List

    5.11 Check List 1. Failure : No cooling (the aggregate at the back of the device is cold). Possible Cause Self Help Authorised Service a.) The thermostat is set to “0”. a.) Set temperature control to middle position. b.) The device plug is not b.) Plug in device plug.
  • Page 15: Technical Data

    5.12 Technical Data Model RH430LD RH440LD RH441LD RH455LD Built-in Built-in Freestanding / Freestanding Built-in Casing Metal Metal Metal Wood Gross Contentss (litres) cooled / uncooled 30 / - 40 / - 40 / - 35 / 20 Dimensions (mm) (H x W xD) 522x384x412 554x401x446 554x401x449...
  • Page 16 Dometic GmbH In der Steinwiese 16 D-57074 Siegen Phone: +49-(0) 271 / 692 0 Fax: +49-(0) 271 / 692 300 www.dometic.de/minibar www.dometic.com © Dometic GmbH - 2002 - Subject to change without notice - Printed in Germany...