Base Sensor Test - Lexmark MS510 Service Manual

Hide thumbs Also See for MS510:
Table of Contents

Advertisement

Sensor Test
This test verifies that the output bin sensors are working correctly.
To run this test:
1
From the Diagnostics menu, navigate to:
Output Bin Tests > Sensor Test > Standard Bin
Testing... appears while the printer is verifying the state of the sensor.
The control panel displays the current state of the sensor.
2
Manually actuate the sensor to make it toggle between empty and full. If the sensor does not toggle, then the
sensor is malfunctioning.
3
Press X to exit the test.

Base Sensor Test

Use the Base sensor test to verify that the sensors located inside the printer are working correctly.
The following sensors can be checked using this test:
Input
Exit
Narrow Media
Front Door
CAUTION—SHOCK HAZARD: The sensor may be electrically energized. To avoid the risk of injury use a non-
conductive implement to toggle the sensors.
To run the Base sensor test:
1
From the Diagnostics menu, navigate to Base Sensor Test.
2
Choose a sensor.
3
Manually actuate the sensor to verify that it toggles. If the sensor does not toggle, then it is malfunctioning.
4
Press X to exit the test.
Sensor
Values
Input
Open
Exit
Closed
Front Door
Narrow Media
Narrow
Wide
Service menus
130
4514-630, -635, -636, -638, -639, -649

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms610M1145M3150

Table of Contents