Power supply

The power supplies are universal and capable of functioning worldwide without
voltage jumpers or switches. They meet IEC 61000-4-5 surge voltage requirements
and are autoranging in terms of accommodating input voltages and line
frequencies. Each power supply has a built-in fan for cooling, pushing air towards
the port side of the switch. Table 15 lists the power supply specifications for the
switch.

Environmental requirements

Table 16 lists the acceptable environmental ranges for both operating and
non-operating (such as during transportation or storage) conditions.
38
SAN06B-R Installation, Service, and User Guide
Table 15. Power supply specifications
Specification
Value
Maximum output
150 Watts
System DC power
Idle: 95 W
consumption (excluding
Maximum: 116 W
power supply/fan
units)
Input system power
Idle: 145 W
(including power
Maximum: 173 W
supply/fan units)
Input voltage
85-264 V ac, Universal
Input line frequency
47-63 Hz
BTU rating
590 BTU/hr
Inrush current
Maximum of 60 amps for period between 10-150 ms
Input line protection
Both AC lines are fused
Table 16. Environmental requirements
Condition
Acceptable range during operation
Ambient
0° to + 40°C (32° to 104°F)
temperature
Humidity
10% to 85% RH non-condensing, at 40°C
(104°F)
Altitude
0 to 3 km (9,842 ft) above sea level
Shock
20 G, 6 ms, half-sine wave
Vibration
0.5 G sine, 5-500 Hz
Air flow
Maximum: 101.94 cmh (60 cfm)
Nominal: 74.76 cmh (44 cfm)
Acceptable range during
non-operation
-25° to 70°C (-13° to 158°F)
10% to 90% RH non-condensing,
at 70°C (158°F)
0 to 12 km (39,370 ft) above sea
level
15 G, 12-18 milliseconds,
trapezoid
2.0 G sine, 5-500 Hz
NA