2. Separate the inner and outer slides.
Figure 5. Separating the inner and outer rails.
3. Install the inner (smaller) slide on the switch chassis, as Figure 4 on page 10
a. Open one of the slides until the lock engages.
b. Press the lock release lever ( 1 in Figure 5) and remove the inner rail from
the outer rail.
1
c. Repeat step 2a and step 2b for the other rail.
Note: For racks with flush-mount doors, such as the 9306 Netfinity
not install the ears. Instead, use the rack-mount slides by attaching the
switch to the set of mounting holes, which are offset 3 inches into the
rack.
shows.
Attention: If you use screws longer than 3/16 in. you can damage the
switch.
a. Position the flat side of the inner rail along one side of the switch. Align the
holes in the rail with the threaded holes in the side of the switch chassis.
The chamfered end of the inner rail should face toward the rear of the
switch (away from the ports) as shown in Figure 6 on page 12.
b. Attach the inner rail by using three of the 8-32 x 3/16 in. zinc screws ( 6 in
Table 5 on page 10).
SJ000046
Chapter 2. Installing and configuring the SAN06B-R
®
racks, do
11