Napoleon GD36NTR Installation And Operation Instructions Manual page 31

Table of Contents

Advertisement

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
Purge all gas lines with the glass door of the fi replace removed. Assure that a continuous gas fl ow is at the burner before installing
the door. When lit for the fi rst time, the fi replace will emit an odour for a few hours. This is a normal temporary condition caused
by the "burn-in" of paints and lubricants used in the manufacturing process and will not occur again.
After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight
odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to suf-
fi ciently ventilate the room.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A. This fi replace is equipped with a pilot which must be lit by hand
while following these instructions exactly.
B. Before operating smell all around the fi replace area for gas and
next to the fl oor because some gas is heavier than air and will
settle on the fl oor.
C. Use only your hand to turn the gas control knob. Never use
tools. If the knob will not turn by hand, do not try to repair it. Call
a qualifi ed service technician. Force or attempted repair may
result in a fi re or explosion.
D. Do not use this fi replace if any part has been under water. Im-
mediately call a qualifi ed service technician to inspect the fi replace
and replace any part of the control system and any gas control
which has been under water.
WARNING: The gas valve has an interlock device which will not
allow the pilot burner to be lit until the thermocouple has cooled.
Allow approximately 60 seconds for the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be turned from
pilot to off unless the knob is depressed slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the fi replace.
3. Turn the gas knob clockwise to off.
4. Wait fi ve (5) minutes to clear out any gas. If you smell gas includ-
ing near the fl oor. Stop! Follow "B" in the above safety information
on this label. If you don't smell gas go the next step.
5. Turn gas knob counter-clockwise to pilot.
1. Turn off all electric power to the fi replace if service is to be
performed.
TURN THE CONTROL VALVE TO THE OFF POSITION WHEN HEATER IS NOT IN USE.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE
SERVICING THE FIREPLACE.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing. This fi replace and its venting
system should be inspected before use and at least annually by a
qualifi ed service person. The fi replace area must be kept clear and
free of combustible materials, gasoline or other fl ammable vapours
and liquids. The fl ow of combustion and ventilation air must not be
obstructed.
1. In order to properly clean the burner and pilot assembly, remove
the logs to expose both assemblies.
2. Keep the control compartment, logs, burner, air shutter opening
and the area surrounding the logs clean by vacuuming or brushing,
at least once a year.
NorthlineExpress.com
OPERATION
WARNING
!
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
• Turn off all gas to the fi replace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbour's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the
fi re department.
LIGHTING INSTRUCTIONS
6. Depress slightly and hold gas knob while lighting the pilot with
the push button igniter. Keep knob depressed for one minute, then
release. If pilot does not continue to burn, repeat steps 3 through
5.
7. With pilot lit, depress and turn gas knob counter-clock-wise to
on.
8. If equipped with remote on-off switch/thermostat, main burner
may not come on when you turn valve to on. Remote switch must
be in the on position to ignite burner.
9. Turn on all
electric power to
the fi replace.
TO TURN OFF GAS
2. Push in gas control knob slightly and turn clockwise to off. Do
not force.
MAINTENANCE
3. Check to see that all burner ports are burning. Clean out any of
the ports which may not be burning or are not burning properly.
4. Check to see that the pilot fl ame is large enough to engulf the
thermocouple and thermopile and reaches toward the burner with
the third jet.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on all open-
ings when the gas knob for the burner is turned on. A 5 to 10 second
total light-up period is satisfactory. If ignition takes longer, consult
your Napoleon dealer / distributor.
7. Check that the gasketing on the sides, top and bottom of the door
is not broken or missing. Replace if necessary.
8. If for any reason the vent air intake system is disassembled,
re-install and re-seal per the instructions provided for the initial
installation.
http://www.northlineexpress.com
WHAT TO DO IF YOU SMELL GAS:
GAS KNOB
31
W415-0210 / R / 02.27.08
Toll-Free 1-866-667-8454

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bgd36ntrBgd36ptrGd36ptr

Table of Contents