OPTIONAL BLOWER INSTALLATION
white
THERMODISC
FIGURE 59
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be electrically connected and grounded in
accordance with local codes. In the absence of local codes,
use the current CSA C22.1 C
or the ANSI/NFPA 70
States
If the fi replace was not previously equipped with a blower:
route a grounded 2-wire, 60hz power cable to the receptacle
/ junction box. At this point, it must be strain relieved and
insulated.
The three slots on the blower mounting bracket allow ease
of adjustment when attaching the blower. For a quiet running
blower, do not allow the assembly to sit on the fi rebox base.
S l i d e t h e v i b r a t i o n
reducing pad (A) into the
clip (C) and up against
the threaded stud (B)
at the other end. The
blower must be able to be
positioned entirely onto
the pad.
To ease installation of the
blower, remove the hinge
screen and valve control door (lower louvres) from the base
of the fi replace.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower does
not touch the fi replace base or the fi rebox.
NorthlineExpress.com
BLOWER
VARIABLE
SPEED
SWITCH
in Canada
ANADIAN ELECTRICAL CODE
in the United
NATIONAL ELECTRICAL CODE
FIGURE 60
http://www.northlineexpress.com
B
A
FIGURE 61
FIGURE 62
Attach the connectors from the black and white wires to the
thermodisc and secure the thermodisc bracket to the securing
stud at the bottom left of the unit using a lock washer and wing
nut. Ensure that the thermodisc touches the fi rebox wall.
Attach the connectors from the black and red wires to the
blower.
THERMODISC
RECEPTACLE /
JUNCTION BOX
GROUND
SCREW
Attach and secure the variable speed switch using the nut
provided. Plug the harness cord into the receptacle.
The wire harness provided in this
kit is a universal harness. When
installed, ensure that any excess
wire is contained, preventing it
from making contact with moving
or hot objects.
Because the blower is thermally
activated, when turned on, it will
automatically start approximately
10 minutes after lighting the
fi replace and will run for approximately 30-45 minutes after
the fi replace has been turned off. Use of the fan increases
the output of heat.
Drywall dust will penetrate into the blower bearings,
causing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or its
compartment. Any damage resulting from this condition is not
covered by the warranty policy.
29
C
FIGURE 63
FIGURE 64
VARIABLE
SPEED
KNOB
W415-0210 / R / 02.27.08