Em Front Panel - Toshiba IPedge Installation Manual

Hide thumbs Also See for IPedge:
Table of Contents

Advertisement

EM SERVER

EM Front Panel

Buttons
LEDs
2-4
The front panel of the IPedge EM server has push-button switches and
LED indicators. the hot-swappable disk drives are accessible from the
front. The redundant power supplies are accessed through the rear panel.
All cable connections are on the rear panel.
Power On/Off Button - This applies or removes system power. When the
power is turned off using this button main power is shut off but standby
power to the system remains on. To completely remove power from the
system use this button to shut down the system then, disconnect both AC
power cords.
System Reset Button - Press and release to reset then, reboot the
server.
UID Button - Unit Identifier: Press once, an LED on the front panel and
an LED on the rear panel illuminate. The LEDs remain lit until the ID
button is pressed again.
Power LED - Indicates that system power is on when illuminated.
Disk drive activity LED - Lights while a hard disk drive or the DVD-ROM
drive is accessed.
NIC 1 - Indicates activity on the LAN 1 connection
NIC 2 - Indicates activity on the LAN 2 connection
Both NIC connections support 10BASE-T, 100BASE-TX, and
1000BASE-T, RJ45 output
UID - Universal Information LED - Refer to the table below for the UID
indications.
Table 2-1 UID LED
UID LED
Fast Flash Red:
Flashing once per second
Solid Red
Slow flash Red:
Flashing once every four seconds
Solid Blue
Flashing blue
Turn off the UID the same way it was lit. If the UID LED was lit by the IPMI
the front panel button will not turn it off. The IPMI must used.
EM Front Panel
Indication
Fan Failure
CPU Overheat
Power fail
UID button pressed
IPMI Activated UID
Installation Manual