Programming (possible only with the remote control RCC-01)

The XP-COMPACT is equipped with a processor fitted out with a Flash Memory,
which means that even when it is disconnected from the battery, the
parameters that were programmed for the application remain after a new
connection to the battery.
It is possible to reinitialize (RESET) the XP-COMPACT by pressing the small
black button on the left of the On/Off or by pressing simultaneously on the
three push buttons 19/20/21 of the remote control during at least 2 seconds. A
beep will confirm the RESET. The inverter switches off after this operation. It
can be turned on again after the beep. The programmed parameters will
remain.
5.1

Standard setting

The XP-COMPACT is delivered with the following default settings:
Auxiliary contact: active in case of defect or manual turn off with the LED 10/11/12/13
Battery voltage :
Absorption Time :
Equalizing Time :
5.2

Reset value (default settings)

To come back to the default settings, press simultaneously on the push buttons
20/21 during at least 2 seconds. A beep will confirm the comeback to the factory
settings. The inverter switches off after this operation. It can be turned on again after
the beep.
5.3

Battery voltages and absorption time

5.3.1 Set the voltage and timing threshold
The programming is done in accordance with
the following steps:
Push and hold down, the Push Button 21
(Program) and the Push Button 19 (Change
status)
for
minimum
simultaneously.
With the Push Button 20 (select) select which
of the battery level and of the absorption time
have to be changed.
These four red LED's show the function set:
Low voltage
Float charge
Absorption (End of charge)
Equalization
Absorption Time
Low voltage
Float Charge
End of Charge Voltage
Equalization
2
seconds
LED 13 (ON/OFF)
LED 12 (Batt. Low/high)
LED 11 (Overload)
LED 10 (Overtemp.)
LED 10/11/12/13 (altogether)
XP-COMPACT V5.7
11.6V / 23.2V / 46.4V
13.5V / 27.0V / 54.0V
14.4V / 28.8V / 57.6V
15.6V / 31.2V / 62.4V
2 Hours
20 Minutes
XP-COMPACT
23/79