Repair Manual
Problem
Subject blurry; image
size accurate.
(2) LCD display problems
Problem
No image in LCD display
screen.
Cause
Not using accessory lens
when taking pictures at
distance of 60 inches
from subject.
Dirty lens.
Improperly seated
accessory closeup lens.
Cause
Check all connections. If
broken or disconnected,
take corrective action. If
not, see below.
System not plugged in. If
not, take corrective
action. If yes, see below.
Check to make sure the
system is turned on. If
there is still no image,
see below.
30
Model 204/404 MiniPortrait Camera
Corrective action
Use accessory closeup
lens when camera-to-
subject distance is 60
inches.
Clean lens with lens
tissue; or use eyeglass
cleaning tissue as
substitute.
Recheck lens seating.
Corrective action
Reconnect or replace as
needed. 20-pin harness
from LCD to logic board;
or 10-pin parallel
harness between power
board and logic board.
Plug one end of AC
adapter into power cord
socket of camera and the
other end into power
source.
Power up the camera by
turning the key
clockwise.