If another than this preferential programmation is required, it can be changed.
type
press
2
7
2
Liquid soap injection
æ
If you have selected some reservoirs of the soapbox (see page 14) for soap injection (yellow colour)
you can now can enter the number of seconds during witch there has to be soap injected in the tub
press
type
press
Time is programmable for 900 seconds maximum, but is limited by the value entered at "TIME".
This can be programmed from 1 to 30 per second, from 31 to 180 per 2 seconds, from 180 to 900 per
5 seconds.
press
press
Overflow cannot be selected if "Pump" was entered at "DRAIN" in configuration menu.
the number of water inlets that have to be avtivated. The following example
will explain this function.
Example :
to select " I2 " and " 7 " (water recovery)
to remove "I2"
a white text block appears.
the number of seconds that soap has to be injected.
to confirm
WATER LEVEL:
Here the water level has to be programmed.
to select :
No level: no water inlet
Low level: low level
High level: high level
Overflow: unlimited level
Remark :