Technical Specifications - Hughes & Kettner SwitchBlade Head 100 Manual

Tube amplifier
Hide thumbs Also See for SwitchBlade Head 100:
Table of Contents

Advertisement

Switchblade
9

Technical Specifications

All level indications relate to 0 dBV (1V RMS).
9.1 Inputs
INSTRUMENT Input
Input:
Type:
Input impedance:
Sensitivity:
Max. Input Level:
FX Return
Input:
Type:
Input impedance:
Max. sensitivity:
Max. Input Level:
MIDI IN
Port:
Data reception:
Channels:
Power supply:
9.2 Outputs
FX Send
Output:
Type:
Output impedance:
Output Level:
Max. output Level:
MIDI THRU
Port:
Data handling:
Speaker Outputs
6.3 mm (1/4") jacks:
Speaker
100 Combo
50 Combo
24
6.3 mm (1/4") jack
unbalanced
1 M ohms
- 50 dB (Clean Channel)
0 dB
6.3 mm (1/4") jack
unbalanced
48 k ohms
-10 dB button engaged: - 21 dB,
disengaged: - 11 dB
-10dB button engaged: + 0 dB,
disengaged + 10 dB
DIN 45 329 (7-pin )
Program change data, Tap Delay function
16, Omni mode
15V DC max. 200mA, pin 6 = positive,
pin 7 = negative
6.3 mm (1/4") jack
unbalanced
2.2 k ohms
+ 3 dB
-10dB button engaged: - 2 dB,
disengaged: + 8 dB
DIN 45 328 ( 5-pin)
All data sent to MIDI IN are patched
out unchanged.
1 x 4 ohms, 2 x 16 ohms / 1 x 8 ohms,
1 x 16 ohms
2 x 12" Eminence® Rockdriver 60
1 x 12" Eminence® Rockdriver 60
9.3 General Electrical Data
Switchblade 100 Head/Combo
Max. current consumption:
440 watts
Max. power consumption:
1.75A @ 240 volts
1.89A @ 220-230 volts
3.50A @ 117-120 volts
3.95A @ 100 volts
Mains voltage tolerance range: +/- 10 %
External fuses (anode):
1 x T 630 mA
Internal fuses:
1 x TT 10 A super slow blow
2 x T 630 mA
Mains fuse (5 x 20 mm):
Europe: (variable: 220 V-230 V / 240 V)
1 x 250 V / T 1.6 A
USA/Canada/Asia: (variable: 100 V / 120 V)
1 x 250 V / T 4 A
Ambient operating temperature range:
0 °C to + 35 °C
9.4 General Mechanical Data
100 Head
Dimensions: (including corners, handles, feet)
Width:
750 mm
Height:
280 mm
Depth:
258 mm
Weight:
17.6 kg
Switchblade 50 Combo
290 watts
0.97A @ 240 volts
1.07A @ 220-230 volts
2.00A @ 117-120 volts
2.15A @ 100 volts
1 x T 400 mA
1 x TT 10 A super slow blow
2 x T 630 mA
1 x 250 V / T 1 A
1 x 250 V / T 2 A
0 °C to + 35 °C
100 Combo
50 Combo
647 mm
600 mm
500 mm
500 mm
285 mm
285 mm
30.3 kg
22.8 kg