INNOVATIVE HEARTH PRODUCTS • SEE-THROUGH POWER VENT DV GAS FIREPLACES (DRT63STYN) • INSTALLATION INSTRUCTIONS
L. Install Firestop/Spacer at exterior wall.
Install SV4.5HF Firestop/Spacer, provided
with the power vent kit, over the opening at
the exterior side of the framing, long side
up, with the 3 inch spacer clearance at the
top as shown in Figure 23, and nail into
place.
(The Firestop/Spacer may also be installed
over the opening at the interior side of the
framing).
M. Install the Power Vent termination.
For the last step, from outside the exterior
wall, slide the collars of the termination onto
the adaptor (the outer inside the outer and
the inner outside the inner) until the termi-
nation seats against the exterior wall sur-
face to which it will be attached. Orient the
housing of the termination with the arrow
pointed upwards. Secure the termination
to the exterior wall. The termination must
not be recessed into the exterior wall or
siding by more that the 1-1/4" (32 mm) as
shown in Figure 24.
The Power Vent termination has been
designed to perform in a wide range of
weather conditions. Our terminations meet
or exceed industry standards.
When selecting the location of your ter-
mination, do not place the termination
where water from eaves and adjoining
roof lines may create a heavy flow of
cascading water onto the terminations. If
the termination must be placed where the
possibility of cascading water exists, it is
the responsibility of the builder to direct
the water away from the termination cap
by using gutters or other means.
Take care to carefully follow the Instal-
lation Instructions for the termination,
including the use of silicone caulking
where required.
See Table 8 as an aid in venting component
selection for a particular range of exterior
wall thicknesses.
IMPORTANT: The vent termination is hot
while in operation and for a period of time
following the use of the fireplace. Young
children should be carefully supervised
when they are in the same area as a hot
termination.
7"
(178)
12-1/8"
(308 mm)
5-1/8"
(130 mm)
Termination
Adaptor
SV4.5RCh
NOTE: Centerline of Vent Piping is
NOT the Same as the Centerline of
the Frame Opening.
6 to 48 inch Vent Section, Telescopic vent
section, Elbow or Appliance Collar
Figure 23: Installing Power Vent Horizontal Termination
*Use silicone caulking to
seal the top and sides of
the termination, up to the
underlayment, stucco, or
Maximum Extent of Vent Run
masonry wall surface.
Sections Relative to Exterior
Siding
Surface of Framing
Caulk*
Caulk*
Stucco
**For thicknesses greater
than 9-1/4", see Table 8
Venting Connection and Exterior Wall Recessing
of the Power Vent horizontal Termination
Figure 24
Venting Components Required for Various Exterior
Wall Thicknesses, When Using The Power Vent Termination
Vent Components Required
Termination Kit Only
Termination Kit and
6 In. Vent Section
(SV4.5L6)
Termination Kit and 12 in. Vent Section
(SV4.5L12)
Termination Kit and Telescopic Section
(SV4.5L12)
Table 8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Firestop/Spacer (SV4.5hF) shown on the
exterior side of the wall. It may also be
installed on the interior side.
10-1/2"
(267 mm)
See Figure 10 on Page 10 for Minimum
Distance to Base of Appliance
Base of Appliance
Interior Surface of
Finished Wall
Last Vent Section.
Use Telescopic Vent
Section (SV4.5LA),
If Necessary
Power Vent
Termination
Termination
Adaptor
SV4.5RCh
Exterior Wall Thickness - inches (mm)
6 to 9-1/4 (152 to 235)
10-3/4 to 14 (273 to 356)
16-3/4 to 20 (426 to 508)
11-3/4 to 20 (299 to 508)
Power Vent
Termination
3"
(76 mm)
1"
(25.4 mm)
Maximum wall thickness
9-1/4 in.(235 mm)**
Exterior Surface of Siding
Exterior Surface of Framing
6 in. to 9-1/4 in.
(152 to 235 mm)**
Power Vent
Termination
1-1/4" Maximum Recess
of the Square Termina-
tion into Exterior Finish-
ing Material
19