Altitude
Maximum input
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
* When the appliance is installed at elevations above 2,000ft and in the absence of specific recommendations
from the local authority having jurisdiction, the certified altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. For rating plate location, see
either "DIMENSIONS" or "RATING PLATE" section. This appliance is not convertible for use with other gases,
unless a certified kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
2.4

RATING PLACE LOCATION

The rating label is located under the control panel and is chained to the appliance. DO NOT REMOVE.
R
CM
REFERENCE #16437
WARNING:
NOT APPROVED FOR USE WITH THIS APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP
18"
SIDES
1"
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
2.5

CARE OF GLASS

DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.
Buff lightly with a clean dry soft cloth. Clean both sides
of the glass after the fi rst 10 hours of operation with a
recommended fi replace glass cleaner. Thereafter clean
as required. If the glass is not kept clean permanent
MATERIAL:
CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
discoloration and / or blemishes may result.
SPECIFICATIONS:
BLACK ON WHITE BACKGROUND, HOLE TO BE 1/4" DIAMETER.
RATES AND EFFICIENCIES
CERTIFIED UNDER : ANSI Z21.11.2-2007 VOLUME II, UNVENTED ROOM HEATER
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME,
WHERE NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON
THE RATING PLATE. THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES.
US
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES ADEQUATE COMBUSTION AND VENTILATION AIR.
MODEL
GVFT8N
(NATURAL GAS)
0-2000FT (0-1370m)
6,000 BTU/h
#56
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
CONTROL: COPRECI T15
OXY PROTECTOR SIT: #9099
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAME. DO NOT USE ACCESSORIES
FLOOR
8"
BACK
0"
NATURAL GAS
0 - 2,000*
6,000
4.5" Water Column
7" Water Column
3.5" Water Column
MODEL
CERTIFIED FOR USA
(PROPANE)
ALTITUDE
INPUT
ORIFICE
MANIFOLD PRESSURE: 10" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
CONTROL: COPRECI T15
OXY PROTECTOR SIT: #9266
MADE IN CANADA
WOLF STEEL LTD, BARRIE, ON, CANADA
GVFT8
SERIAL NUMBER:
!
PROPANE
0 - 2,000*
6,000
11" Water Column
13" Water Column
10" Water Column
GVFT8P
0-2000FT (0-1370m)
6,000 BTU/h
#69
W385-0480
WARNING
!
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
5.1
AVERTISSEMENT
7
W415-0847 / 09.15.09