Enter The Heating Program; Enter The Cooling Program - White Rodgers 1F95-1291 Installation And Operating Instructions Manual

Big blue humidity universal non-programmable touchscreen thermostat with humidity/dehumidity control and automatic heat/cool changeover option
Hide thumbs Also See for 1F95-1291:
Table of Contents

Advertisement

PROGRAMMING
4) If you wish to copy to all days skip to next step or press
Advance Day until the day you wish to copy to is fl ashing.
5) Press Copy. "Copy" will disappear, the day you copied
from will disappear and the day(s) you copied to will be on.
6) If you wish to copy this same program into other days,
press Copy and repeat steps 3, 4 and 5.
7) Press Run Schedule to return to normal operation.
Fill in the blank schedule on the next page then:

Enter the Heating Program

1) Press the Menu button and then press Set Schedule.
Press SYSTEM button to select either "Heat" or "Cool" in
the system switch area indicating the active mode being
programmed. You can switch to the other mode by press-
ing the system switch at any time.
2) The top of the display will show the day(s) being pro-
grammed. The time and set at temperature are also
displayed. "Morning" will also be displayed to indicate
the period.
3) Press the key to change the temperature to your selected
temperature for the 1st heating period (Morning).
4) Press
or
key to adjust the start time for period.
The time will change in 15 minute increments.
5) Press FAN to select Auto or Prog.
6) After you have set the time and the temperature for the
period to begin, press Set Schedule to advance to the
next program period.
7) Repeat steps 2 through 6 until all of the program times
and temperatures are set for all program periods on
that day.
8) Press "Advance Day" to change to the next day and
repeat steps 2 through 8.
9) When programming is complete and all of the times and
temperatures match your desired heating schedule,
press Run Schedule. The thermostat will now run your
program.

Enter the Cooling Program

1) Press the SYSTEM button until the Cool icon appears.
2) Follow Enter Heating Program instructions for entering
cooling times and temperatures.
Automatic Schedule
This feature provides a method to program every day with the
most popular time and temperature settings using one key.
For this feature to be available, the Auto Schedule options
(Installer/Confi guration menu item 17, AS Heat, or item 18,
AS Cool) must be selected On.
Energy Saving Factory Pre-Program
The 1F95-1291 thermostats are programmed with the energy saving settings shown in the table below for all days of the week.
If this program suits your needs, simply set the thermostat clock and press the RUN button.
The table below shows the factory set heating and cooling schedule for all days of the week.
Heating
6:00 AM
Program
Cooling
6:00 AM
Program
* You can eliminate these two program periods in the confi guration menu (reference #5) if the building is occupied all day.
Day period will change to 6:00 AM and 70° and can be programmed as required.
* Wake Up
Leave For Work
(Morning)
(Day)
70°F
8:00 AM
75°F
8:00 AM
To use Auto Schedule, press Run Schedule to be sure you
are in normal operating mode. In SYSTEM Heat mode, use
the keys to select your "Comfort Temperature". When your
"Comfort Temperature" is selected, press Auto Schedule key.
The key will begin to fl ash indicating that the feature is ready
to store your selected temperature. Press Auto Schedule a
second time to complete the process. The Auto Schedule
key will disappear to indicate that the Auto Schedule com-
mand has been accepted.
In Heat mode the thermostat will maintain your "Comfort Tem-
perature" during the Morning, Day and Evening periods and
setback 6° for the Night. Morning period will begin at 6:30 AM
and Night period will begin at 10:30 PM.
To set the Auto Schedule temperature for Cool mode, press
SYSTEM to change the mode to Cool and repeat setting the
temperature. In Cool mode, the thermostat will maintain your
selected "Comfort Temperature" continuously.
The "Comfort Temperature" can be temporarily overridden by
changing the setpoint temperature using the
Once Auto Schedule has been set and the key has disap-
peared, it can be reset in the Installer/ Confi guration menu.
Entering Fan Program
In the Set Schedule mode, the FAN key is used to select the
fan operation during a program period. The default state of
the Fan key is FAN Auto (fan runs during a call for cool, but
not on a call for heat). It can be changed to FAN Prog (fan
runs during a program period). Each press of the FAN key
will change the mode of the fan between Auto and Prog. In
the Run mode, when a program period that has FAN Prog
begins, the fan will turn on and stay on during the complete
period. The display will show FAN On Prog.
In the Run mode, pressing the FAN key will change the fan
from Auto (default setting) to On (fan running continuously)
or Prog. When FAN Prog is displayed, the fan will run when
the system cycles. If the system does not cycle for more than
60 minutes, the thermostat will turn the fan on for 10 minutes
and off for 20 minutes to improve indoor air quality. If the
display shows FAN On Prog to indicate the program period
has the fan programmed to run, FAN Prog will override the
programmed setting until Run Schedule is pressed or the
next schedule period begins.
* Return Home
(Evening)
62°F
5:00 PM
70°F
83°F
5:00 PM
75°F
or
keys.
Go To Bed
(Night)
10:00 PM
62°F
10:00 PM
78°F
11