Adjustment - Canon SmartBase MPC600F Service Manual

Hide thumbs Also See for SmartBase MPC600F:
Table of Contents

Advertisement

SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service

3. ADJUSTMENT

3.1 CS LED Lights-on Duration Adjustment
a) Overview
This adjustment is used to eliminate uneven scanning which can result from variations in light intensity
between individual LED's. Performing the adjustment will therefore have an effect on scanned and
copied images.
The adjustment value is registered in an SRAM IC which has lithium battery back-up and will not be lost
even if power is turned off. However, the SRAM data can become damaged, for example by battery
depletion. In this case, the machine checks the data's validity the next time power is turned ON. If the
data is invalid, the adjustment is made automatically. Because the user is automatically prompted, it is
almost never necessary to perform this adjustment during normal use. However, if the SCNT board,
Contact sensory ass'y, or lithium battery is replaced, be sure to perform this adjustment. Also, if the
color or brightness of scanned or copied images is faulty, performing this adjustment may correct the
problem.
b) Procedure
(1) Check that the ADF or pressure plate is closed correctly, then perform the adjustment by following
the steps described below.
SERVICE MODE
TEST MODE
1
2-1 ADJ LED TIME
[1]----[2]
Several seconds later
Figure 4-2 CS LED Lights-on Duration Adjustment Operation
(2) The adjustment procedure is finished when the display reads TEST MODE.
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
Menu
Copy
FOR 300 DPI CS
TEST MODE [1] - [4]
CF-FH : EC-02-01
Display TEST MODE by
#
pressing
2-1 ADJ LED TIME
OK
2
1
[1]----[2]
Several seconds later
FOR 600 DPI CS
2
4-6
button
2
1