#3 NUMERIC PARAM (numeric parameter settings)
No.
10
11
[Parameter 10]
The "wait time after transmission of a dialing signal ends until a significant signal is detected in
transmission" was set as T1 timer with parameter 10.
However, ITU-T recommends that it should be set as T0 timer, so parameter 10 has been renamed to
T0 timer and the default time-out time has been changed from 35 to 55 seconds.
NOTE
[Parameter 11]
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is
received).
If frequent errors occur during reception (2 instances) because of line connection conditions, raise
the value of this parameter.
#7 PRINTER (printer function settings)
2. NUMERIC PARAM.
No.
05
[Parameter 05]
Sets the bottom margin for B/W printing (Copy & Fax). This parameter also sets the margins when
PRINT MARGIN in user data is set to SMALLER for color printing.
5. INK ABS CAPA
This switch allows the waste ink capacity stored in the PCNT board to be checked or entered.
[SUCTION]
This allows the waste ink capacity for the ink absorbed during cleaning to be checked or entered.
When entering the waste ink capacity, use the numeric buttons to enter a value 0 to 100 (%).
NOTE
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service
Function
T0 Timer
T1 Timer (Rx)
The T1 timer for the transmitter (wait time after a CED, V21 flag, or ANSam significant
signal is detected until the next significant signal is detected) is fixed at 35 seconds.
Function
Trailing edge margin
for black&white copy & FAX
The ink absorber's absorption capacity for the waste ink discharged by the BJ cartridge is
set to a certain amount. The waste ink capacity settings are stored in the PCNT board's
EEPROM. When replacing the PCNT board, check the waste ink capacity and enter the
waste ink capacity into the new PCNT board.
The various waste ink capacity can be checked with the SYSTEM DUMP LIST.
Selecting range
0~9999
0~9999
Selecting range
0 ~ 9999
4-45
Default setting
5500 (55 second)
3500 (35 second)
Default setting
5 ( 5 mm)