1.6.5 SIT MILLIVOLT 820 NOVA REMOTE CONTROLLED SYSTEM REQUIRING A
DOUBLE POLE SWITCH
NOTE: Must use double pole switch (supplied) or double pole thermostat (not supplied) with specifi c
power vent adaptor kits.
NOTE: Downward venting is not allowed with appliances that use standing pilots.
THERMOPILE
Pilot Assembly
Receiver
BLOWER
VAC SWITCH
YELLOW
YELLOW
GPV Terminal
Disconnect one of the two wires from the receiver to the valve. Connect it to one of the yellow
1.
wires from the power vent control module.
Connect a jumper wire to the valve where the receiver wire was disconnected and to the other yellow
2.
wire from the power vent control module.
PILOT
BURNER
THERMOCOUPLE
RED
WHITE
GREEN
Double Pole
Switch
SIT Millivolt Gas Valve
1
2
YELLOW
YELLOW
13
Power Vent
Control
Module
Appliance
Junction Box