Electrical Box Installation; Restrictor Plate Installation; Wiring Diagram And Installation - Napoleon GPV GAS POWER VENT Installation Instructions Manual

Direct vent terminal
Hide thumbs Also See for GPV GAS POWER VENT:
Table of Contents

Advertisement

8

1.4.7 ELECTRICAL BOX INSTALLATION

NOTE: Before fi nishing in the appliance, the power vent must be installed.
EN
POWER VENT
CONTROL
MODULE
Start by removing the pre-fi nishing access panel or opening lower louvre.
A.
Position the Power Vent Control Module in a convenient location (not on top of the heat shield in the
B.
LHD50) and Velcro it to the base of the appliance.
Slide the 20' (6.1m) power vent cable through the right side of the appliance and connect the box
C.
connector to the side panel, see "INSTALLATION OVERVIEW" section for illustration.
Feed the wires through the inside panel, slide the split bushing over the coated wires and snap into the
D.
7/8" (22.2mm) hole to protect the wires as illustrated. Attach the connections as per the appropriate
wiring diagram. See "WIRING DIAGRAM AND INSTALLATION" section.
Plug the power vent control module into either the appliance junction box or the control module, if
E.
equipped.
1.5

RESTRICTOR PLATE INSTALLATION

REFER TO PVA KIT FOR APPLIANCE SPECIFIC INSTRUCTIONS.
1.6

WIRING DIAGRAM AND INSTALLATION

Connect the wiring to the power vent termination as outlined in the previous section, and connect the wiring
to the appliance as outlined in the schematic below. Ensure that the proper clearances are maintained for the
wiring and conduit. When installing the wiring it must never run above the vent run and it must be a minimum
1" (25.4mm) from all venting.
NOTE: The GPV includes a 20 foot (6.1m) wire harness. If this harness does not reach the appliance,
then it may be cut and a splice added. These connections must conform with local codes or, in the ab-
sence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA
70 National Electrical Code in the United States.
W415-1160 / 03.06.13
JUNCTION BOX
CONTROL MODULE
LHD50 ILLUSTRATED
BX SNAP
BUSHING
20' (6.1m)
POWER VENT
CABLE
SPLIT BUSHING
REQUIRED

Advertisement