10-3-6. Indoor Unit Fixing

1. Pass the pipe through the hole in the wall and
hook the indoor unit on the installation plate at
the upper hook.
2. Swing the indoor unit to right and left to confirm
that it is firmly hooked on the installation plate.
3. While pressing the indoor unit onto the wall, hook
it at the lower part on the installation plate.
Pull the indoor unit toward you to confirm that it is
firmly hooked on the installation plate.
Hook here
1
1 Installation
plate
2
Hook
Fig. 10-4-22
• For detaching the indoor unit from the mounting
plate, pull the indoor unit toward you while pushing
its bottom up at the specified parts.
Push
Fig. 10-4-23
Information
The lower part of indoor unit may float, due to the
condition of piping and you cannot fix it to the
installation plate. In that case, use the
trovided to fix the unit and the installation plate.
9
Fig. 10-4-24
Push (unhook)
Push
9
screws
9
Screw
Screw
10-3-7. Drainage
1. Run the drain hose at a downward sloped angle.
NOTE :
• Hole should be made at a slight downward slant
on the outdoor side.
Do not rise the drain hose.
2 in.
(50 mm)
or more
2. Put water in the drain pan and make sure that the
water is being drained outside.
3. When connecting extension drain hose, insulate
the connection part of extension drain hose with
shield pipe.
Drain hose
Arrange the drain pipe for proper drainage from
the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed
to drain water collected from dew, which forms
on the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
– 64 –
FILE NO. SVM-13070-2
CAUTION
Do not form the drain hose
into the waved shape.
Do not put the
Do not put the drain
drain hose end
hose end in the
into water.
drainage ditch.
Fig. 10-4-25
Shield pipe
CAUTION
Inside the room
Extension drain hose
Fig. 10-4-26
CAUTION
Wall
Drain
guide
Space for
pipes
Fig. 10-4-27