Indoor Unit Fixing; Drainage - Toshiba RAS-25S4KVDG-ND Installation Manual

Hide thumbs Also See for RAS-25S4KVDG-ND:
Table of Contents

Advertisement

Available languages

Available languages

CAUTION
• Bind the auxiliary pipes (two), power supply and connecting cable with
facing tape tightly.
Power supply and
connecting cable
Indoor unit
• Carefully arrange pipes so that any pipe does not stick out of the rear
plate of the indoor unit.
• Carefully connect the auxiliary pipes and connecting pipes to one
another and cut off the insulating tape wound on the connecting pipe
to avoid double-taping at the joint;
moreover, seal the joint with the vinyl tape, etc.
• Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
• When bending a pipe, carefully do it, not to crush it.

Indoor Unit Fixing

CAUTION
• The air inlet grille should be removed before installing the indoor unit.
To avoid damage to the corner of the air inlet grille or the wall.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Pass the pipe through the hole in the wall and hook the indoor unit on the
installation plate at the upper hook.
3. Swing the indoor unit to right and left to confirm that it is firmly hooked up
on the installation plate.
4. While pressing the indoor unit onto the wall, hook it at the lower part on
the installation plate. Pull the indoor unit toward you to confirm that it is
firmly hooked up on the installation plate.
2
Press indoor unit
to lower hook
• For detaching the indoor unit from the installation plate, pull the indoor unit
toward you while pushing its bottom up at the specified parts.
Push
Push
1
Installation plate
Auxiliary pipes
1
Hang indoor unit's
hook here
1
Installation plate
Press
(unhook)
INFORMATION
• The lower part of indoor unit may float, due to the condition of piping
and installer cannot fix it to the installation plate. In that case, use the
screws provided to fix the indoor unit with the installation plate.
• Especially when the pipes are pulled out to the left side, the indoor
unit must be screwed to the installation plate.
8
Screw
1. Run the drain hose sloped downwards.
NOTE
• The hole should be made at a slight downward slant on the outdoor side.
Do not rise the
drain hose.
50 mm
or more
2. Put water in the drain pan and make sure that the water is drained out of
doors.
3. When connecting extension drain hose, insulate the connecting part of
extension drain hose with shield pipe.
Drain hose
CAUTION
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed
to drain water collected from dew, which forms
on the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
10
Installation plate
Indoor unit
8
Screw
Screw
8

Drainage

Do not form the
drain hose into
a wavy shape.
Do not put the
drain hose end
into water.
Shield pipe
Extension drain hose
Inside the room
Space for pipes
1
Wall
Do not put the
drain hose end in the
drainage ditch.
Wall
Drain
guide