Toshiba RAS-15EKV-UL Service Manual page 104

Indoor and outdoor unit air conditioner split tye
Hide thumbs Also See for RAS-15EKV-UL:
Table of Contents

Advertisement

No.
Part name
Control board
assembly
Procedure
1. Disconnect the leads and connectors connected to
the other parts from the control board assembly.
1) Leads
• 3 leads (black, white, orange) connected to
terminal block.
• Lead connected to compressor :
Disconnect the connector (3P).
• Lead connected to reactor :
Disconnect the two connectors (2P).
2) Connectors (×8)
CN300 : Outdoor fan motor (3P: white)*
(* : See Note)
CN701 : 4-way valve (2P: yellow)*
CN600 : TE sensor (2P: white)*
CN700 : PMV (6P: white)
CN603 : TS sensor (3P: white)*
CN601 :TD sensor (3P: white)*
CN602 : TO sensor (2P: white)
CN500 : Pressure SW. (2P:white)
CN703 : Heater cord. (2P:white)
These connectors have a disconnect prevention
mechanism: as such, the lock on their housing
must be released before they are disconnected.
2. Remove the control board assembly from the P .C.
board base. (Remove the heat sink and control
board assembly while keeping them screwed
together.)
Disengage the four claws of the P .C. board base,
hold the heat sink, and lift to remove it.
3. Remove the two fixing screws used to secure the
heat sink and control board assembly.
4. Mount the new control board assembly.
When mounting the new control board assembly,
ensure that the P .C. board is inserted properly
into the P .C. board support groove.
NOTE
NOTE
NOTE
– 104 –
FILE NO. SVM-13070
Remarks
CN603
CN601
CN600
CN701
CN500
CN700
CN602 CN300
CN300, CN701, CN600 and
CN603 are connectors with
locking mechanisms: as such,
to disconnect them, they must
be pressed in the direction of
the arrow while pulling them
out.
P.C. board base